Managing Postoperative Artifacts on Computed Tomography and Magnetic Resonance Imaging

被引:40
作者
Buckwalter, Kenneth A. [1 ]
Lin, Chen [1 ]
Ford, Jason M. [1 ]
机构
[1] Indiana Univ Hosp, Dept Radiol, Indianapolis, IN 46202 USA
关键词
Tomography; X-ray computed; magnetic resonance imaging; joint prostheses; orthopedic fixation devices; CT; REDUCTION; ALGORITHM; IMPLANTS;
D O I
10.1055/s-0031-1286013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Orthopedic hardware should not be considered a contraindication to computed tomography (CT) or magnetic resonance (MR) imaging. The hardware alloy, the geometry of the hardware, and the orientation of the hardware all affect the magnitude of image artifacts. For commonly encountered alloys, the severity of image artifacts is similar for CT and MR. Cobalt chrome or stainless steel hardware produces the most artifacts; titanium hardware produces the least. In general, image artifacts are most severe adjacent to the hardware. CT image artifacts are related to incomplete X-ray projection data resulting in streaks. These can be mitigated by increasing scan technique and using a smoother reconstruction filter. Hardware with a rectangular cross-sectional shape such as a fixation plate will cause more artifacts than a radially symmetrical device such as an intramedullary nail. Image artifacts at MR are caused by the hardware magnetic susceptibility and the induction of eddy currents within the metal. A turbo spin-echo sequence yields the best results. The use of larger image matrices, thinner slices, and a wide receiver bandwidth are recommended parameter adjustments when imaging patients with hardware. This article discusses how hardware-related artifacts can be minimized by altering scan technique and image reconstruction.
引用
收藏
页码:309 / 319
页数:11
相关论文
共 16 条
[1]
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[2]
Multichannel CT imaging of orthopedic hardware and implants [J].
Buckwalter, KA ;
Parr, JA ;
Choplin, RH ;
Capello, WN .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2006, 10 (01) :86-97
[3]
Optimizing imaging techniques in the postoperative patient [J].
Buckwalter, Kenneth A. .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2007, 11 (03) :261-272
[4]
SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[5]
Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[6]
Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT [J].
Lee, Mi-Jung ;
Kim, Sungjun ;
Lee, Sung-Ah ;
Song, Ho-Taek ;
Huh, Yong-Min ;
Kim, Dae-Hong ;
Han, Seung Hwan ;
Suh, Jin-Suck .
RADIOGRAPHICS, 2007, 27 (03) :791-803
[7]
LIN C, 2009, 17 SCI M INT SOC MAG
[8]
Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress [J].
Liu, Patrick T. ;
Pavlicek, William P. ;
Peter, Mary B. ;
Spangehl, Mark J. ;
Roberts, Catherine C. ;
Paden, Robert G. .
SKELETAL RADIOLOGY, 2009, 38 (08) :797-802
[9]
Mahnken AH, 2003, INVEST RADIOL, V38, P769, DOI 10.1097/01.rli.0000086495.96457.54
[10]
Radiation exposures to patients from CT: Reality, public perception, and policy [J].
Nickoloff, EL ;
Alderson, PO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) :285-287