Single Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes

被引:131
作者
Popescu, Florin [1 ]
Fazli, Siamac [1 ]
Badower, Yakob [1 ]
Blankertz, Benjamin [1 ,2 ]
Mueller, Klaus-R. [1 ,2 ]
机构
[1] Fraunhofer Inst FIRST, Intelligent Data Anal Lab, Berlin, Germany
[2] Tech Univ Berlin, Machine Learning Lab, Berlin, Germany
来源
PLOS ONE | 2007年 / 2卷 / 07期
关键词
D O I
10.1371/journal.pone.0000637
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background. Brain computer interfaces (BCI) based on electro-encephalography (EEG) have been shown to detect mental states accurately and non-invasively, but the equipment required so far is cumbersome and the resulting signal is difficult to analyze. BCI requires accurate classification of small amplitude brain signal components in single trials from recordings which can be compromised by currents induced by muscle activity. Methodology/Principal Findings. A novel EEG cap based on dry electrodes was developed which does not need time-consuming gel application and uses far fewer electrodes than on a standard EEG cap set-up. After optimizing the placement of the 6 dry electrodes through off-line analysis of standard cap experiments, dry cap performance was tested in the context of a well established BCI cursor control paradigm in 5 healthy subjects using analysis methods which do not necessitate user training. The resulting information transfer rate was on average about 30% slower than the standard cap. The potential contribution of involuntary muscle activity artifact to the BCI control signal was found to be inconsequential, while the detected signal was consistent with brain activity originating near the motor cortex. Conclusions/Significance. Our study shows that a surprisingly simple and convenient method of brain activity imaging is possible, and that simple and robust analysis techniques exist which discriminate among mental states in single trials. Within 15 minutes the dry BCI device is set-up, calibrated and ready to use. Peak performance matched reported EEG BCI state of the art in one subject. The results promise a practical non-invasive BCI solution for severely paralyzed patients, without the bottleneck of setup effort and limited recording duration that hampers current EEG recording technique. The presented recording method itself, BCI not considered, could significantly widen the use of EEG for emerging applications requiring longterm brain activity and mental state monitoring.
引用
收藏
页数:5
相关论文
共 17 条
  • [1] The thought-translation device (TTD):: Neurobehavioral mechanisms and clinical outcome
    Birbaumer, N
    Hinterberger, T
    Kübler, A
    Neumann, N
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) : 120 - 123
  • [2] A spelling device for the paralysed
    Birbaumer, N
    Ghanayim, N
    Hinterberger, T
    Iversen, I
    Kotchoubey, B
    Kübler, A
    Perelmouter, J
    Taub, E
    Flor, H
    [J]. NATURE, 1999, 398 (6725) : 297 - 298
  • [3] BLANKERTZ B, 2007, NEUROIMAGE IN PRESS
  • [4] Blankertz B, 2006, J UNIVERS COMPUT SCI, V12, P581
  • [5] The BCI competition III:: Validating alternative approaches to actual BCI problems
    Blankertz, Benjamin
    Mueller, Klaus-Robert
    Krusienski, Dean J.
    Schalk, Gerwin
    Wolpaw, Jonathan R.
    Schloegl, Alois
    Pfurtscheller, Gert
    Millan, Jose D. R.
    Schroeder, Michael
    Birbaumer, Niels
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (02) : 153 - 159
  • [6] The Berlin brain-computer interface:: EEG-based communication without subject training
    Blankertz, Benjamin
    Dornhege, Guido
    Krauledat, Matthias
    Mueller, Klaus-Robert
    Kunzmann, Volker
    Losch, Florian
    Curio, Gabriel
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2006, 14 (02) : 147 - 152
  • [7] Impact of activity and arousal upon spectral EEG parameters
    Bonnet, MH
    Arand, DL
    [J]. PHYSIOLOGY & BEHAVIOR, 2001, 74 (03) : 291 - 298
  • [8] Dornhege G., 2007, BRAIN COMPUTER INTER
  • [9] Scalp electrode placement by EC2® adhesive paste in long-term video-EEG monitoring
    Falco, C
    Sebastiano, F
    Cacciola, L
    Orabona, F
    Ponticelli, R
    Stirpe, P
    Di Gennaro, G
    [J]. CLINICAL NEUROPHYSIOLOGY, 2005, 116 (08) : 1771 - 1773
  • [10] FARQUHAR J, 2006, REGULARISED CSP SENS, P14