Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma

被引:306
作者
Nelson, RE [1 ]
Grebe, SK [1 ]
O'Kane, DJ [1 ]
Singh, RJ [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Lab Med & Pathol, Rochester, MN 55905 USA
关键词
D O I
10.1373/clinchem.2003.025478
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Estradiol (E2) and estrone (E1) measurements form an integral part of the assessment of female reproductive function and have expanding roles in other fields. However, many E1 and E2 immunoassays have limited functional sensitivity, suffer from cross-reactivity, and display poor intermethod agreement. To overcome these problems, we developed a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the simultaneous measurement of E1 and E2. Methods: After dansyl chloride derivatization, samples were separated by fast gradient chromatography and injected into a tandem mass spectrometer after formation of positive ions with atmospheric pressure chemical ionization. The limits of detection and quantification, recovery, linearity, precision, and reference intervals were determined, and performance was compared with several immunoassays. Results: Total run time per sample was 5 min. The multiple-reaction monitoring ion pairs were m/z 506/171 for 3-dansyl-estradiol and m/z 504/171 for 3-dansylestrone. The limits of detection for E1 and E2 were 12.9 pmol/L (3.5 ng/L) and 10.3 pmol/L (2.8 ng/L), respectively. Interassay imprecision (CV) was 4-20% (n = 20). The limits of quantification (functional sensitivities) for E1 and E2 were 44.1 pmol/L (11.9 ng/L) and 23.2 pmol/L (6.3 ng/L), respectively. The assay was linear to >2200 pmol/L (similar to600 ng/L) for each analyte. Recoveries were 93-108% for E1 and 100-110% for E2. No cross-reactivity was observed. Method comparison with several immunoassays revealed that the latter were inaccurate and prone to interferences at low E1 and E2 concentrations. Conclusions: LC-MS/MS allows rapid, simultaneous, sensitive, and accurate quantification of E1 and E2 in human serum. (C) 2004 American Association for Clinical Chemistry.
引用
收藏
页码:373 / 384
页数:12
相关论文
共 45 条
[1]   Association of hypogonadism and estradiol levels with bone mineral density in elderly men from the framingham study [J].
Amin, S ;
Zhang, YQ ;
Sawin, DT ;
Evans, SR ;
Hannan, MT ;
Kiel, DP ;
Wilson, PWF ;
Felson, DT .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (12) :951-963
[2]   Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma [J].
Anari, MR ;
Bakhtiar, R ;
Zhu, B ;
Huskey, S ;
Franklin, RB ;
Evans, DC .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4136-4144
[3]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[4]   Diagnosis of late puberty [J].
Argente, J .
HORMONE RESEARCH, 1999, 51 :95-100
[5]   Determination of 17β-estradiol in bovine plasma:: development of a highly sensitive technique by ion trap gas chromatography-tandem mass spectrometry using negative chemical ionization [J].
Biancotto, G ;
Angeletti, R ;
Traldi, P ;
Silvestri, M ;
Saccon, M ;
Guidugli, F .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (12) :1266-1271
[6]   PLASMA ESTROGENS IN CHILDHOOD AND PUBERTY UNDER PHYSIOLOGIC AND PATHOLOGIC CONDITIONS [J].
BIDLINGMAIER, F ;
WAGNERBA.M ;
BUTENANDT, O ;
KNORR, D .
PEDIATRIC RESEARCH, 1973, 7 (11) :901-907
[7]  
Carlstrom K, 1996, Acta Obstet Gynecol Scand Suppl, V163, P11
[8]  
Choi MH, 2000, ANALYST, V125, P711
[9]   Serum estradiol level and risk of breast cancer during treatment with raloxifene [J].
Cummings, SR ;
Duong, T ;
Kenyon, E ;
Cauley, JA ;
Whitehead, M ;
Krueger, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (02) :216-220
[10]   Derivatization procedures for the detection of estrogenic chemicals by gas chromatography/mass spectrometry [J].
Ding, WH ;
Chiang, CC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :56-63