A brief status on condition monitoring and fault diagnosis in wind energy conversion systems

被引:350
作者
Amirat, Y. [1 ,2 ]
Benbouzid, M. E. H. [1 ]
Al-Ahmar, E. [1 ,3 ]
Bensaker, B. [2 ]
Turri, S. [1 ]
机构
[1] Univ Brest, EA 4325, LBMS, F-29238 Brest, France
[2] Univ Annaba, Dept Elect Engn, Annaba 23000, Algeria
[3] Holy Spirit Univ Kaslik, Fac Sci & Comp Engn, Jounieh, Lebanon
关键词
Wind turbine; Induction generator; Drive train; Condition monitoring; Fault diagnosis; DAMAGE-DETECTION; POWER; MOTORS;
D O I
10.1016/j.rser.2009.06.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
There is a constant need for the reduction of operational and maintenance costs of Wind Energy Conversion Systems (WECSs). The most efficient way of reducing these costs would be to continuously monitor the condition of these systems. This allows for early detection of the degeneration of the generator health, facilitating a proactive response, minimizing downtime, and maximizing productivity. Wind generators are also inaccessible since they are situated on extremely high towers, which are normally 20 m or more in height. There are also plans to increase the number of offshore sites increasing the need for a remote means of WECS monitoring that eliminates some of the difficulties faced due to accessibility problems. Therefore and due to the importance of condition monitoring and fault diagnosis in WECS (blades, drive trains, and generators), and keeping in mind the need for future research, this paper is intended as a brief status describing different types of faults, their generated signatures, and their diagnostic schemes. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2629 / 2636
页数:8
相关论文
共 36 条
[21]   Experience with bicoherence of electrical power for condition monitoring of wind turbine blades [J].
Jeffries, WQ ;
Chambers, JA ;
Infield, DG .
IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1998, 145 (03) :141-148
[22]  
KHAN MM, 2005, P IEEE CCECE 05
[23]   Induction motor fault diagnosis based on neuropredictors and wavelet signal processing [J].
Kim, K ;
Parlos, AG .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2002, 7 (02) :201-219
[24]  
KRAMER S, 2006, P IEEE INT C MULT FU, P173
[25]   Model of stator inter-turn short circuit fault in doubly-fed induction generators for wind turbine [J].
Lu, QF ;
Cao, ZT ;
Ritchie, E .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :932-937
[26]  
MIHETPOPA L, 2003, P IEEE IAS 03, P1839
[27]   Fault detection in a multistage gearbox by demodulation of motor current waveform [J].
Mohanty, A. R. ;
Kar, Chinmaya .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) :1285-1297
[28]   Condition monitoring and fault diagnosis of electrical motors - A review [J].
Nandi, S ;
Toliyat, HA ;
Li, XD .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) :719-729
[29]   Maintenance management of wind power systems using condition monitoring systems - Life cycle cost analysis for two case studies [J].
Nilsson, Julia ;
Bertling, Lina .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :223-229
[30]  
TAVNER PJ, 2006, J WIND ENERGY, V10, P1