Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma

被引:79
作者
Alnouti, Y [1 ]
Srinivasan, K [1 ]
Waddell, D [1 ]
Bi, HG [1 ]
Kavetskaia, O [1 ]
Gusev, AI [1 ]
机构
[1] Pfizer Inc, Global Res & Dev, Pharmacokinet Dynam & Metab, Groton, CT 06340 USA
关键词
LC-MS/MS; SPE; plasma;
D O I
10.1016/j.chroma.2005.04.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C-18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C 18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 42 条
[1]  
Ayrton J, 1999, RAPID COMMUN MASS SP, V13, P1657, DOI 10.1002/(SICI)1097-0231(19990830)13:16<1657::AID-RCM694>3.0.CO
[2]  
2-L
[3]   Optimisation and routine use of generic ultra-high flow-rate liquid chromatography with mass spectrometric detection for the direct on-line analysis of pharmaceuticals in plasma [J].
Ayrton, J ;
Dear, GJ ;
Leavens, WJ ;
Mallett, DN ;
Plumb, RS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :199-207
[4]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[5]  
2-Z
[6]  
BERNA MJ, 2004, CHEM ACTA, V1, P1
[7]  
Dear G, 2001, RAPID COMMUN MASS SP, V15, P152, DOI 10.1002/1097-0231(20010130)15:2<152::AID-RCM206>3.3.CO
[8]  
2-R
[9]   A rapid and sensitive method for simultaneous determination of lamivudine and zidovudine in human serum by on-line solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry detection [J].
Estrela, RDCE ;
Salvadori, MC ;
Suarez-Kurtz, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (10) :1147-1155
[10]   Combined electrospray ionization-atmospheric pressure chemical ionization source for use in high-throughput LC-MS applications [J].
Gallagher, RT ;
Balogh, MP ;
Davey, P ;
Jackson, MR ;
Sinclair, I ;
Southern, LJ .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :973-977