Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma

被引:79
作者
Alnouti, Y [1 ]
Srinivasan, K [1 ]
Waddell, D [1 ]
Bi, HG [1 ]
Kavetskaia, O [1 ]
Gusev, AI [1 ]
机构
[1] Pfizer Inc, Global Res & Dev, Pharmacokinet Dynam & Metab, Groton, CT 06340 USA
关键词
LC-MS/MS; SPE; plasma;
D O I
10.1016/j.chroma.2005.04.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C-18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C 18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 42 条
[11]   Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry [J].
Grant, RP ;
Cameron, C ;
Mackenzie-McMurter, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1785-1792
[12]  
Haque A, 1999, BIOMED CHROMATOGR, V13, P51, DOI 10.1002/(SICI)1099-0801(199902)13:1<51::AID-BMC814>3.3.CO
[13]  
2-K
[14]   Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography [J].
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :3-54
[15]   Increasing throughput of parallel on-line extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development [J].
Hsieh, S ;
Tobien, T ;
Koch, K ;
Dunn, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (03) :285-292
[16]   Direct plasma analysis of drug compounds using monolithic column liquid chromatograpy and tandem mass spectrometry [J].
Hsieh, Y ;
Wang, GF ;
Wang, YG ;
Chackalamannil, S ;
Kortmacher, WA .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1812-1818
[17]   Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry [J].
Hsieh, Y ;
Wang, GF ;
Wang, YG ;
Chackalamannil, S ;
Brisson, JM ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) :944-950
[18]   Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry [J].
Hsieh, YS ;
Bryant, MS ;
Brisson, JM ;
Ng, KK ;
Korfmacher, WA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (02) :353-362
[19]   Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry [J].
Hsieh, YS ;
Chintala, M ;
Mei, H ;
Agans, J ;
Brisson, JM ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) :2481-2487
[20]  
Hsieh YS, 2000, RAPID COMMUN MASS SP, V14, P1384, DOI 10.1002/1097-0231(20000815)14:15<1384::AID-RCM32>3.0.CO