Increasing throughput of parallel on-line extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development

被引:62
作者
Hsieh, S
Tobien, T
Koch, K
Dunn, J
机构
[1] GlaxoSmithKline Inc, Res Triangle Pk, NC 27709 USA
[2] Leap Technol, Carrboro, NC 27510 USA
关键词
D O I
10.1002/rcm.1327
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An approach is described with turbulent flow on-line extraction liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for GLP quantitative bioanalysis of a drug candidate. Two systems were built in-house with standard laboratory parts and equipments. One system consisted of one gradient HPLC pump, one isocratic pump, one ten-port valve, two turbulent flow columns, one analytical column, one autosampler and one mass spectrometer. Using this system, an injection-to-injection cycle time of 0.8 min was achieved. By adding an additional valve, another analytical column and an isocratic pump, the injection-to-injection cycle time decreased to 0.4 min. Validation results from the two systems showed that precision and accuracy were acceptable for GLP quantitative analyses. The system was utilized to support sample bioanalysis of a drug candidate in a first-time in-human clinical trial. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:285 / 292
页数:8
相关论文
共 27 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]  
[Anonymous], 2001, FDA GUIDANCE IND BIO
[4]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[5]  
2-Z
[6]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[7]   Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry [J].
Grant, RP ;
Cameron, C ;
Mackenzie-McMurter, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1785-1792
[8]   Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography [J].
Herman, JL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (05) :421-426
[9]  
Jemal M, 1998, RAPID COMMUN MASS SP, V12, P1389, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1389::AID-RCM329>3.3.CO