YAP-PET:: first results of a small animal Positron Emission Tomograph based on YAP:Ce finger crystals

被引:79
作者
Del Guerra, A
Di Domenico, G
Scandola, M
Zavattini, G
机构
[1] Univ Ferrara, Dipartimento Fis, I-44100 Ferrara, Italy
[2] Ist Nazl Fis Nucl, Sez Ferrara, I-44100 Ferrara, Italy
关键词
D O I
10.1109/23.737671
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have built a small animal Positron Emission Tomograph (YAP-PET) based on four matrices of 400 YAP:Ce finger crystals (2x2x30 mm(3) each) coupled to Position Sensitive PhotoMultiplier Hamamatsu R2486-06. The system consists of four detectors on a rotating gantry with a variable diameter from 10 and 25 cm. The read-out and data acquisition system are handled by NIM-CAMAC standard electronics. The tomograph has a total Field Of View (FOV) of 4x4x4 cm(3) that is appropriate for mice and rat studies. A spatial resolution less than or equal to 2 mm over 3x3x3 cm(3) FOV has been measured, with a peak sensitivity for a point source of about 614 cps/mu Ci for a gantry diameter of 15 cm and an energy The system consists of four detectors on a rotating gantry with threshold of 50 keV.
引用
收藏
页码:3105 / 3108
页数:4
相关论文
共 10 条
  • [1] BEVILACQUA A, 1997, UNPUB IEEE T NUCL SC
  • [2] THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH
    BLOOMFIELD, PM
    RAJESWARAN, S
    SPINKS, TJ
    HUME, SP
    MYERS, R
    ASHWORTH, S
    CLIFFORD, KM
    JONES, WF
    BYARS, LG
    YOUNG, J
    ANDREACO, M
    WILLIAMS, CW
    LAMMERTSMA, AA
    JONES, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) : 1105 - 1126
  • [3] Sub-millimeter planar imaging with positron emitters: EGS4 code simulation and experimental results
    Bollini, D
    DelGuerra, A
    DiDomenico, G
    Galli, M
    Gambaccini, M
    Zavattini, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) : 1499 - 1502
  • [4] INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA
    CLACK, R
    TOWNSEND, D
    JEAVONS, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) : 1421 - 1431
  • [5] FULLY 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY
    COLSHER, JG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) : 103 - 115
  • [6] CUTLER PD, 1992, J NUCL MED, V33, P595
  • [7] Use of a YRP:Ce matrix coupled to a position-sensitive photomultiplier for high resolution position emission tomography
    DelGuerra, A
    deNotaristefani, F
    DiDomenico, G
    Giganti, M
    Pani, R
    Piffanelli, A
    Zavattini, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1958 - 1962
  • [8] DELGUERRA A, 1998, IN PRESS NUCL INSTR
  • [9] HICHWA R, 1994, J NUCL MED, V35, P1396
  • [10] MARRIOTT CJ, 1994, J NUCL MED, V35, P1390