Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice

被引:85
作者
Ishibe, S
Peixoto, AJ
机构
[1] Yale Univ, Sch Med, Nephrol Sect, New Haven, CT USA
[2] VA Connecticut Healthcare Syst, Renal Sect, West Haven, CT USA
关键词
D O I
10.1111/j.1525-139X.2004.17112.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Determining dry weight and assessing extracellular fluid volume in hemodialysis (HD) patients is one of the greatest challenges to practicing nephrologists. The clinical examination has limited accuracy, so different strategies have been investigated to aid in this evaluation. Biochemical markers of volume overload (ANP, BNP, cGMP) are fraught with excessive variability and poor correlation with volume status. Inferior vena cava ultrasound is effective, but cumbersome and costly. Bioimpedance measurements of intra- and extracellular water have significant shortcomings when used as isolated measurements, but can be useful in following trends over time and have been shown to improve intradialytic symptoms and blood pressure control. Continuous blood volume monitoring is helpful in preventing intradialytic hypotension and may help identify patients who are volume overloaded and need increased ultrafiltration. In this review we discuss these different techniques and other developments in the evaluation of dry weight and volume status, which may enhance our ability to improve patient stability and well-being during HD sessions.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 56 条
[1]  
[Anonymous], 2001, Handbook of dialysis
[2]   Can the clinical examination diagnose left-sided heart failure in adults? [J].
Badgett, RG ;
Lucey, CR ;
Mulrow, CD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (21) :1712-1719
[3]   Arterial compliance by cuff sphygmomanometer - Application to hypertension and early changes in subjects at genetic risk [J].
Brinton, TJ ;
Kailasam, MT ;
Wu, RA ;
Cervenka, JH ;
Chio, SS ;
Parmer, RJ ;
DeMaria, AN ;
OConnor, DT .
HYPERTENSION, 1996, 28 (04) :599-603
[4]   Development and validation of a noninvasive method to determine arterial pressure and vascular compliance [J].
Brinton, TJ ;
Cotter, B ;
Kailasam, MT ;
Brown, DL ;
Chio, SS ;
OConnor, DT ;
DeMaria, AN .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (03) :323-330
[5]   Circulating natriuretic peptide concentrations in patients with end-stage renal disease: Role of brain natriuretic peptide as a biomarker for ventricular remodeling [J].
Cataliotti, A ;
Malatino, LS ;
Jougasaki, M ;
Zoccali, C ;
Castellino, P ;
Giacone, G ;
Bellanuova, I ;
Tripepi, R ;
Seminara, G ;
Parlongo, S ;
Stancanelli, B ;
Bonanno, G ;
Fatuzzo, P ;
Rapisarda, F ;
Belluardo, P ;
Signorelli, SS ;
Heublein, DM ;
Lainchbury, JG ;
Leskinen, HK ;
Bailey, KR ;
Redfield, MM ;
Burnett, JC .
MAYO CLINIC PROCEEDINGS, 2001, 76 (11) :1111-1119
[6]   Assessing fluid change in hemodialysis: Whole body versus sum of segmental bioimpedance spectroscopy [J].
Chanchairujira, T ;
Mehta, RL .
KIDNEY INTERNATIONAL, 2001, 60 (06) :2337-2342
[7]   Adjusting dry weight by extracellular volume and body composition in hemodialysis patients [J].
Chen, YC ;
Chen, HH ;
Yeh, JC ;
Chen, SY .
NEPHRON, 2002, 92 (01) :91-96
[8]  
CHERIEX EC, 1989, NEPHROL DIAL TRANSPL, V4, P563
[9]   CLINICAL-ASSESSMENT OF EXTRACELLULAR FLUID VOLUME IN HYPONATREMIA [J].
CHUNG, HM ;
KLUGE, R ;
SCHRIER, RW ;
ANDERSON, RJ .
AMERICAN JOURNAL OF MEDICINE, 1987, 83 (05) :905-908
[10]   BNP and congestive heart failure [J].
Cowie, MR ;
Mendez, GF .
PROGRESS IN CARDIOVASCULAR DISEASES, 2002, 44 (04) :293-321