Chemiluminescence determination of chlorinated volatile organic compounds by conversion on nanometer TiO2

被引:64
作者
Liu, GH
Zhu, YF
Zhang, XR [1 ]
Xu, BQ
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] Tsing Hua Univ, State Key Lab C1 Chem & Technol, Beijing 100084, Peoples R China
关键词
D O I
10.1021/ac025882u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method based on conversion of chlorinated volatile organic compounds (CVOCs) to chlorine using a new type of column packed with nanometer TiO2 coupled with chemiluminescence (CL) has been developed for determination of them in workplace air. CVOCs are converted to chlorine by nanometer TiO2 at 220 degreesC. The Cl-2 that is produced is selectively enriched on the column and subsequently released from the column at 600 degreesC. The Cl-2 that is released is determined using a postcolumn CL detector. The CL intensity was linear with CCl4 in the range of 0.1-380 ppm, and the detection limit was 40 ppb (S/N = 3). Higher sensitivity could be acquired by using a larger volume of enrichment. A similar procedure could be used for the determination of other CVOCs. CL intensities of CH2Cl2, CHCl3, and CCl4 at the same concentration increased in the order CH2Cl2 < CHCl3 < CCl4. The method has been successfully applied to the determination of CCl4 in workplace air, where 0.15-150 ppm CCl4 would be detected. The possible mechanism for the long lifetime of the column packed with nanometer TiO2 was tested using Raman spectrometer, X-ray powder diffraction, transmission electron microscopy and X-ray photoelectron spectroscopy. The results showed that the column packed with nanometer TiO2 could be operated in the reversible mode for determination of CVOCs under the present conditions. The method would be potentially applied to the analysis of other chlorinated compounds in environment, such as persistent organic pollutants.
引用
收藏
页码:6279 / 6284
页数:6
相关论文
共 27 条
[1]   Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy [J].
Arena, MP ;
Porter, MD ;
Fritz, JS .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :185-190
[2]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828
[3]   Analysis of cocaine, benzoylecgonine, codeine, and morphine in hair by supercritical fluid extraction with carbon dioxide modified with methanol [J].
Brewer, WE ;
Galipo, RC ;
Sellers, KW ;
Morgan, SL .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2371-2376
[4]   Nanostructures: Introduction [J].
Chandross, EA ;
Miller, RD .
CHEMICAL REVIEWS, 1999, 99 (07) :1641-1642
[5]   HYDROTHERMAL PREPARATION OF UNIFORM NANOSIZE RUTILE AND ANATASE PARTICLES [J].
CHENG, HM ;
MA, JM ;
ZHAO, ZG ;
QI, LM .
CHEMISTRY OF MATERIALS, 1995, 7 (04) :663-671
[6]  
Ferrer I, 2002, ANAL CHEM, V74, P1275, DOI 10.1021/ac010969l
[7]   FT-Raman spectroscopy and density functional theory studies on silica-supported rhodium complexes [J].
Gbureck, A ;
Kiefer, W ;
Schneider, ME ;
Werner, H .
VIBRATIONAL SPECTROSCOPY, 1998, 17 (01) :105-115
[8]   Esculetin prevents liver damage induced by paracetamol and CCl4 [J].
Gilani, AH ;
Janbaz, KH ;
Shah, BH .
PHARMACOLOGICAL RESEARCH, 1998, 37 (01) :31-35
[9]   Matrix effect in the cryotrapping of gas samples in the ppbv range [J].
Görgényi, M ;
Dewulf, J ;
Van Langenhove, H .
CHROMATOGRAPHIA, 2000, 51 (7-8) :461-466
[10]   AUTOMATED IN-SITU GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF PPT LEVEL VOLATILE ORGANIC TRACE GASES USING MULTISTAGE SOLID-ADSORBENT TRAPPING [J].
HELMIG, D ;
GREENBERG, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) :123-132