An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component

被引:108
作者
Corten, K. [1 ]
Vanrykel, F. [1 ]
Bellemans, J. [1 ]
Frederix, P. Reynders [1 ]
Simon, J. -P. [1 ]
Broos, P. L. O. [1 ]
机构
[1] Univ Hosp, Louvain, Belgium
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2009年 / 91B卷 / 11期
关键词
DALL-MILES CABLE; SHAFT FRACTURES; PLATE FIXATION; HIP-REPLACEMENT; VANCOUVER CLASSIFICATION; ARTHROPLASTY; ALLOGRAFTS; TYPE-B1; STEMS;
D O I
10.1302/0301-620X.91B11.22292
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored. Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed. Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.
引用
收藏
页码:1424 / 1430
页数:7
相关论文
共 37 条
[1]
Percutaneous plate fixation for periprosthetic femoral fractures - a preliminary report [J].
Abhaykumar, S ;
Elliott, DS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (08) :627-630
[2]
Outcome following stabilization of type B1 periprosthetic femoral fractures [J].
Agarwal, S ;
Andrews, CM ;
Bakeer, GM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :118-121
[3]
TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[4]
The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :249-+
[5]
The reliability and validity of the Vancouver classification of femoral fractures after hip replacement [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :59-62
[6]
Locking compression plate fixation of Vancouver type-b1 periprosthetic femoral fractures [J].
Buttaro, M. A. ;
Farfalli, G. ;
Nunez, M. Paredes ;
Comba, F. ;
Piccaluga, F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :1964-1969
[7]
Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients [J].
Chakravarthy, Jagannath ;
Bansal, Rajeev ;
Cooper, Julian .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :725-733
[8]
Chandler HP, 1998, AAOS INSTR COURS LEC, V47, P257
[9]
Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
Di Cesare, PE .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :177-180
[10]
Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528