Robust 3-D modeling of vasculature imagery using superellipsoids

被引:98
作者
Tyrrell, James Alexander
di Tomaso, Emmanuelle
Fuja, Daniel
Tong, Ricky
Kozak, Kevin
Jain, Rakesh K.
Roysam, Badrinath [1 ]
机构
[1] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
[2] Massachusetts Gen Hosp, Edwin L Steele Lab, Dept Radiat Oncol, Charlestown, MA 02129 USA
关键词
robust detection/estimation; superellipsoid; vessel detection/segmentation;
D O I
10.1109/TMI.2006.889722
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents methods to model complex vasculature in three-dimensional (3-D) images using cylindroidal superellipsoids, along with robust estimation and detection algorithms for automated image analysis. This model offers an explicit, low-order parameterization, enabling joint estimation of boundary, centerlines, and local pose. It provides a geometric framework for directed vessel traversal, and extraction of topological information like branch point locations and connectivity. M-estimators provide robust region-based statistics that are used to drive the superellipsoid toward a vessel boundary. A robust likelihood ratio test is used to differentiate between noise, artifacts, and other complex unmodeled structures, thereby verifying the model estimate. The proposed methodology behaves well across scale-space, shows a high degree of insensitivity to adjacent structures and implicitly handles branching. When evaluated on synthetic imagery mimicking specific structural complexities in tumor microvasculature, it consistently produces ubvoxel accuracy estimates of centerlines and widths in the presence of closely-adjacent vessels, branch points, and noise. An edit-based validation demonstrated a precision level of 96.6% at a recall level of 95.4%. Overall, it is robust enough for large-scale application.
引用
收藏
页码:223 / 237
页数:15
相关论文
共 45 条
[41]   Model-based method for improving the accuracy and repeatability of estimating vascular bifurcations and crossovers from retinal fundus images [J].
Tsai, CL ;
Stewart, CV ;
Tanenbaum, HL ;
Roysam, B .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (02) :122-130
[42]   A 2-D/3-D model-based method to quantify the complexity of microvasculature imaged by in vivo multiphoton microscopy [J].
Tyrrell, JA ;
Mahadevan, V ;
Tong, RT ;
Brown, EB ;
Jain, RK ;
Roysam, B .
MICROVASCULAR RESEARCH, 2005, 70 (03) :165-178
[43]  
VERDONCK B, 1995, COMPUTER ASSISTED RADIOLOGY, P177
[44]  
WEBSTER R, 1995, CONVEXITY
[45]  
Winkler F, 2004, CANCER CELL, V6, P553, DOI 10.1016/j.ccr.2004.10.011