A comparison of the pulsed, lock-in and frequency modulated thermography nondestructive evaluation techniques

被引:150
作者
Chatterjee, Krishnendu [1 ]
Tuli, Suneet [1 ]
Pickering, Simon G. [2 ]
Almond, Darryl P. [2 ]
机构
[1] Indian Inst Technol, Ctr Appl Res Elect, Delhi 110016, India
[2] Univ Bath, Dept Mech Engn, UK Res Ctr NDE, Bath BA2 7AY, Avon, England
关键词
Pulsed thermography; Lock-in thermography; Blind frequency; FMTWI; Matched energy comparison; Image fusion;
D O I
10.1016/j.ndteint.2011.06.008
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Pulsed, lock-in and frequency modulated thermography are three alternative nondestructive evaluation techniques. The defect imaging performance of these techniques are compared using: matched excitation energy: the same carbon fiber composite test piece and infrared camera system. The lock-in technique suffers from "blind frequencies" at which phase images for some defects disappear. It is shown that this problem can be overcome by using frequency modulated (chirp) excitation and an image fusion algorithm is presented that enhance phase imaging of defects. The signal-to-noise ratios (SNRs) of defect images obtained by the three techniques are presented. For the shallowest defects (depths 0.25 and 0.5 mm, 6 mm diameter), the pulsed technique exhibits the highest SNRs. For deeper defects the SNRs of the three techniques are similar in magnitude under matched excitation energy condition. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:655 / 667
页数:13
相关论文
共 13 条
[1]  
Almond D., 1996, PHOTOTHERMAL SCI TEC
[2]   Evaluation of defects in composite plates under convective environments using lock-in thermography [J].
Bai, W ;
Wong, BS .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (02) :142-150
[3]   THERMAL WAVE IMAGING WITH PHASE SENSITIVE MODULATED THERMOGRAPHY [J].
BUSSE, G ;
WU, D ;
KARPEN, W .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (08) :3962-3965
[4]   A QUANTITATIVE-ANALYSIS OF PULSED VIDEO THERMOGRAPHY [J].
LAU, SK ;
ALMOND, DP ;
MILNE, JM .
NDT & E INTERNATIONAL, 1991, 24 (04) :195-202
[5]   Advances in pulsed phase thermography [J].
Maldague, X ;
Galmiche, F ;
Ziadi, A .
INFRARED PHYSICS & TECHNOLOGY, 2002, 43 (3-5) :175-181
[6]   Pulse phase infrared thermography [J].
Maldague, X ;
Marinetti, S .
JOURNAL OF APPLIED PHYSICS, 1996, 79 (05) :2694-2698
[7]  
MILNE JM, 1985, P SOC PHOTO-OPT INST, P119
[8]   Theory of frequency modulated thermal wave imaging for nondestructive subsurface defect detection [J].
Mulaveesala, Ravibabu ;
Tuli, Suneet .
APPLIED PHYSICS LETTERS, 2006, 89 (19)
[9]   An evaluation of the performance of an uncooled microbolometer array infrared camera for transient thermography NDE [J].
Pickering, S. G. ;
Almond, D. P. .
NONDESTRUCTIVE TESTING AND EVALUATION, 2007, 22 (2-3) :63-70
[10]   Matched excitation energy comparison of the pulse and lock-in thermography NDE techniques [J].
Pickering, Simon ;
Almond, Darryl .
NDT & E INTERNATIONAL, 2008, 41 (07) :501-509