Clinical application of laser-induced breakdown spectroscopy to the analysis of teeth and dental materials

被引:41
作者
Samek, O
Liska, M
Kaiser, J
Beddows, DCS
Telle, HH
Kukhlevsky, SV
机构
[1] Tech Univ Brno, Inst Engn Phys, Brno 61669, Czech Republic
[2] Univ Coll Swansea, Dept Phys, Swansea SA2 8PP, W Glam, Wales
[3] Janus Pannonius Univ, Dept Phys, H-7624 Pecs, Hungary
来源
JOURNAL OF CLINICAL LASER MEDICINE & SURGERY | 2000年 / 18卷 / 06期
关键词
D O I
10.1089/clm.2000.18.281
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: The luminous plasma generated during laser ablation of dental tissue and dental materials has been analyzed to determine qualitative and quantitative elemental composition, Background Data: The use of pulsed lasers for controlled material ablation now is frequently suggested as an alternative to mechanical drilling for the removal of caries and in tooth modification. Spectral analysis of the ablated plasma can be exploited to monitor precisely the laser drilling process in vivo and in real time. Methods: Teeth samples and dental materials were ablated using pulses from a Nd:YAG laser. The line positions and intensities in the spectra, recorded in real time, were used to identify elements and to determine their relative concentrations. Results: From the spectra of horizontally and vertically cut tooth slices, profiles of elemental distribution were determined; these were used in a range of monitoring applications. We showed that the transition from caries to healthy tooth material could be identified through the decrease in calcium (Ca) and phosphorus (P) concentrations, whereas nonmineralizing elements and organic materials increased in concentration. We also could relate the spatial distribution of elements to their migration or accumulation over time, for example, the migration of aluminium (Al) from dental restorative materials to the tooth matrix. Conclusions: The plasma existing during laser ablation (in vitro/in vivo) can be analyzed spectrally in real time. From the spectra, one can pinpoint high/low levels of element concentrations within the tooth matrix. Thus, this analysis could be used to monitor the ablation of material during laser dental treatment.
引用
收藏
页码:281 / 289
页数:9
相关论文
共 31 条
  • [11] Laser induced breakdown spectroscopy (LIBS) as an analytical tool for the detection of metal ions in aqueous solutions
    Knopp, R
    Scherbaum, FJ
    Kim, JI
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (01): : 16 - 20
  • [12] Effective laser ablation of enamel and dentine without thermal side effects
    Kohns, P
    Zhou, P
    Stormann, R
    [J]. JOURNAL OF LASER APPLICATIONS, 1997, 9 (03) : 171 - 174
  • [13] Krüger J, 1999, LASER PHYS, V9, P30
  • [14] Femtosecond-pulse laser ablation of dental hydroxyapatite and single-crystalline fluoroapatite
    Krüger, J
    Kautek, W
    Newesely, H
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1999, 69 : S403 - S407
  • [15] Use of laser ablation inductively coupled plasma mass spectrometry to provide element versus time profiles in teeth
    Lee, KM
    Appleton, J
    Cooke, M
    Keenan, F
    Sawicka-Kapusta, K
    [J]. ANALYTICA CHIMICA ACTA, 1999, 395 (1-2) : 179 - 185
  • [16] Characterization of enamel and dentin response to Nd:YAG picosecond laser ablation
    Lizarelli, RFZ
    Kurachi, C
    Misoguti, L
    Bagnato, VS
    [J]. JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 1999, 17 (03): : 127 - 131
  • [17] Multi-element profiling of human deciduous teeth by laser ablation-inductively coupled plasma-mass spectrometry
    Lochner, F
    Appleton, J
    Keenan, F
    Cooke, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) : 299 - 306
  • [18] Laser-induced optical breakdown on hard and soft tissues and its dependence on the pulse duration: Experiment and model
    Loesel, FH
    Niemz, MH
    Bille, JF
    Juhasz, T
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1996, 32 (10) : 1717 - 1722
  • [19] MURRAY JJ, 1990, PREVENTION DENTAL DI
  • [20] Niemz M., 1996, Laser-Tissue Interactions