Tissue harmonic imaging: Why does it work?

被引:175
作者
Thomas, JD [1 ]
Rubin, DN [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol F15, Cleveland, OH 44195 USA
关键词
D O I
10.1016/S0894-7317(98)70055-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The recent utilization of harmonic frequencies in the imaging of both tissue and contrast agents has dramatically improved echocardiographic image quality. In contrast harmonics, the harmonic frequency energy is generated on reflection from the microbubble contrast agent. In tissue harmonics, the harmonic frequency energy is generated gradually as the ultrasonic wave propagates through the tissue. Critical to the utility of tissue-generated harmonic frequencies is their origin beyond the chest wall and their nonlinear relation to the fundamental frequency energy strength. These two characteristics of tissue-generated harmonics ensure that the echoes most likely to produce artifact are least likely to produce harmonic waves. Armed with an understanding of how these images are produced and with data emerging as to their clinical utility, we anticipate that harmonic imaging will become the standard for assessing regional and global left ventricular function in technically difficult studies.
引用
收藏
页码:803 / 808
页数:6
相关论文
共 18 条
[1]   DETERMINATION OF NONLINEARITY PARAMETER B/A FOR WATER AND META-XYLENE [J].
ADLER, L ;
HIEDEMANN, EA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (04) :410-&
[2]  
Averkiou MA, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P1561, DOI 10.1109/ULTSYM.1997.663294
[3]   Measurements of harmonic generation in a focused finite-amplitude sound beam [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (06) :3439-3442
[4]  
Block R J, 1996, J Am Soc Echocardiogr, V9, P787, DOI 10.1016/S0894-7317(96)90469-1
[5]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[6]   Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems [J].
Christopher, T ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :1103-1116
[7]   New ultrasound contrast agents and technological innovations [J].
deJong, N ;
TenCate, FJ .
ULTRASONICS, 1996, 34 (2-5) :587-590
[8]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[9]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .2. MEASUREMENTS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :455-459
[10]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .1. SIMULATIONS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :447-453