Tissue harmonic imaging: Why does it work?

被引:175
作者
Thomas, JD [1 ]
Rubin, DN [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol F15, Cleveland, OH 44195 USA
关键词
D O I
10.1016/S0894-7317(98)70055-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The recent utilization of harmonic frequencies in the imaging of both tissue and contrast agents has dramatically improved echocardiographic image quality. In contrast harmonics, the harmonic frequency energy is generated on reflection from the microbubble contrast agent. In tissue harmonics, the harmonic frequency energy is generated gradually as the ultrasonic wave propagates through the tissue. Critical to the utility of tissue-generated harmonic frequencies is their origin beyond the chest wall and their nonlinear relation to the fundamental frequency energy strength. These two characteristics of tissue-generated harmonics ensure that the echoes most likely to produce artifact are least likely to produce harmonic waves. Armed with an understanding of how these images are produced and with data emerging as to their clinical utility, we anticipate that harmonic imaging will become the standard for assessing regional and global left ventricular function in technically difficult studies.
引用
收藏
页码:803 / 808
页数:6
相关论文
共 18 条
[11]   Real-time assessment of the parameter of nonlinearity in tissue using ''nonlinear shadowing'' [J].
Fatemi, M ;
Greenleaf, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1215-1228
[12]   Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex [J].
Lindner, JR ;
Dent, JM ;
Moos, SP ;
Jayaweera, AR ;
Kaul, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (12) :1657-1662
[13]   A comparison of frequency conversion technology, power motion imaging, and intravenous Albunex for improved endocardial border resolution in patients with technically difficult echocardiograms [J].
Main, ML ;
Asher, CR ;
Odabashian, JA ;
Cardon, LA ;
Klein, AL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :77A-77A
[15]   REAL-TIME IMAGE-PROCESSING BASED ON NONLINEAR MODELS WITH APPLICATIONS TO IMAGE-ENHANCEMENT, AREA DETECTION AND VOLUME VISUALIZATION [J].
OLSTAD, B .
ULTRASCHALL IN DER MEDIZIN, 1993, 14 (05) :210-213
[16]   Why does tissue harmonic imaging improve image quality: A quantitative examination demonstrating side-lobe suppression [J].
Rubin, DN ;
Yazbek, N ;
Homa, D ;
Odabashian, J ;
Livisi, B ;
Stewart, WJ ;
Thomas, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :127A-127A
[17]   Harmonic imaging with levovist [J].
Schwarz, KQ ;
Chen, XC ;
Steinmetz, S ;
Phillips, D .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (01) :1-10
[18]  
YAZBEK N, 1998, J AM COLL CARDIOL, V32, pA127