Nondestructive determination of the ambroxol content in tablets by Raman spectroscopy

被引:39
作者
Hwang, MS
Cho, S
Chung, H [1 ]
Woo, YA
机构
[1] Hanyang Univ, Coll Nat Sci, Dept Chem, Seoul 133791, South Korea
[2] Dongduk Womens Univ, Coll Pharm, Seoul 136814, South Korea
关键词
ambroxol; Raman spectroscopy; partial least-squares; wavelet transformation;
D O I
10.1016/j.jpba.2004.12.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a method for determining the ambroxol content in tablets nondestructively. To obtain a reliable quantitative calibration, we prepared 20 pellet samples (ambroxol content: 8.30-16.25 wt.%) and acquired their Raman spectra while rotating the pellets. The spectra of the rotated samples reflected the compositional variations better than those that were recorded without rotation. To reduce both the baseline variations and the spectral noise simultaneously, the spectra were pre-processed using wavelet transformation (WT). Then, we used the normalization method before partial least-squares (PLS) regression to correct Raman intensity variation from laser power fluctuation. The achieved standard error of cross validation (SECV) was 0.30%. Two different datasets where Raman intensity was artificially changed were prepared and the corresponding spectra were quantitatively analyzed. The result was reproducible even if laser intensity was fairly changed. Additionally, two different commercial tablets were analyzed and the accuracy of measurement was better for a tablet that had the similar spectral features of the standard pellet samples. The proposed method can be utilized for the analysis of commercial tablets if standard tablets of various ambroxol concentrations that have the same chemical components including additives and the same physical shape of tablets are available. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
[Anonymous], 1998, Chemometrics: A Practical Guide
[3]   THE WAVELET TRANSFORM FOR PREPROCESSING IR-SPECTRA IN THE IDENTIFICATION OF MONOSUBSTITUTED AND DISUBSTITUTED BENZENES [J].
BOS, M ;
VRIELINK, JAM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 23 (01) :115-122
[4]  
CHUI CK, 1991, INTRO WAVELETS
[5]   Feasibility of simultaneous measurement of xylene isomers and other hydrocarbons in p-xylene production processes using near-infrared spectroscopy [J].
Chung, H ;
Lee, JS ;
Ku, MS .
APPLIED SPECTROSCOPY, 1998, 52 (06) :885-889
[6]   Quantitative determination of ambroxol in tablets by derivative UV spectrophotometric method and HPLC [J].
Dinçer, Z ;
Basan, H ;
Göger, NG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) :867-872
[7]   QUANTITATIVE-DETERMINATION OF AMBROXOL HYDROCHLORIDE IN TABLETS [J].
INDRAYANTO, G ;
HANDAYANI, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) :781-784
[8]   Rapid and nondestructive analysis of the ethylene content of propylene/ethylene copolymer by near-infrared spectroscopy [J].
Lee, JS ;
Chung, H .
VIBRATIONAL SPECTROSCOPY, 1998, 17 (02) :193-201
[9]   Raman spectroscopy [J].
Mulvaney, SP ;
Keating, CD .
ANALYTICAL CHEMISTRY, 2000, 72 (12) :145R-157R
[10]   Quantitative analysis using Raman spectrometry [J].
Pelletier, MJ .
APPLIED SPECTROSCOPY, 2003, 57 (01) :20A-42A