Stroke volume equation for impedance cardiography

被引:138
作者
Bernstein, DP [1 ]
Lemmens, HJM
机构
[1] Palomar Med Ctr, Dept Anesthesiol, Escondido, CA USA
[2] Stanford Univ, Sch Med, Dept Anesthesiol, Stanford, CA 94305 USA
关键词
stroke volume; cardiac output; impedance cardiography; acceleration; dZ/dt(max);
D O I
10.1007/BF02344724
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
The study's goal was to determine if cardiac output (CO), obtained by impedance cardiography (ICG), would be improved by a new equation N, implementing a square root transformation for dZ/dt(max)/Z(0), and a variable magnitude, mass-based volume conductor V-C. Pulmonary artery catheterisation was performed on 106 cardiac surgery patients pre-operatively. Post-operatively, thermodilution cardiac output (TDCO) was simultaneously compared with ICG CO. dZ/dt(max)/Z(0) and Z(0) were obtained from a proprietary bioimpedance device. The impedance variables, in addition to left ventricular ejection time T-LVE and patient height and weight, were input using four stroke volume (SW equations: Kubicek (K), Sramek (S), Sramek- Bernstein (SB), and a new equation N. CO was calculated as SV x heart rate. Data are presented as mean +/- SD. One way repeated measures of ANOVA followed by the Tukey test were used for inter-group comparisons. Bland-Altman methods were used to assess bias, precision and limits of agreement. P < 0.05 was considered statistically significant. CO implementing N (6.06 +/- 1.48 l min(-1)) was not different from TDCO (5.97 +/- 1.41 l min(-1)). By contrast, CO calculated using K (3.70 +/- 1.53 l min(-1)), S (4.16 +/- 1.83 l min(-1)) and SB (4.37 +/- 1.82 l min(-1)) was significantly less than TDCO. Bland-Altman analysis showed poor agreement between TDCO and K, S and SB, but not between TDCO and N. Compared with TDCO, equation N, using a square-root transformation for dZ/dt(max)/Z(0), and a mass-based V-C, was superior to existing transthoracic impedance techniques for SV and CO determination.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 53 条
[1]
Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients [J].
Axler, O ;
Tousignant, C ;
Thompson, CR ;
DallavaSantucci, J ;
Phang, PT ;
Russell, JA ;
Walley, KR .
JOURNAL OF CRITICAL CARE, 1996, 11 (03) :109-116
[2]
BAUSEL RB, 2002, POWER ANAL EXPT RES, P179
[3]
A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
Brock H, 2002, EUR J ANAESTH, V19, P288
[7]
Relations of stroke volume and cardiac output to body composition - The strong heart study [J].
Collis, T ;
Devereux, RB ;
Roman, MJ ;
de Simone, G ;
Yeh, JL ;
Howard, BV ;
Fabsitz, RR ;
Welty, TK .
CIRCULATION, 2001, 103 (06) :820-825
[8]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[9]
The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill [J].
Critchley, LAH ;
Calcroft, RM ;
Tan, PYH ;
Kew, J ;
Critchley, JAJH .
INTENSIVE CARE MEDICINE, 2000, 26 (06) :679-685
[10]
STABILITY OF CARDIAC IMPEDANCE MEASURES - AORTIC OPENING (B-POINT) DETECTION AND SCORING [J].
DEBSKI, TT ;
ZHANG, YX ;
JENNINGS, JR ;
KAMARCK, TW .
BIOLOGICAL PSYCHOLOGY, 1993, 36 (1-2) :63-74