The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill

被引:34
作者
Critchley, LAH [1 ]
Calcroft, RM
Tan, PYH
Kew, J
Critchley, JAJH
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Anaesthesia & Intens Care, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Div Clin Pharmacol, Shatin, Hong Kong, Peoples R China
关键词
cardiac output; bioimpedance; thermodilution; sepsis; pulmonary oedema; lung injury score;
D O I
10.1007/s001340051232
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Objectives: To investigate the relationship between the attenuation of impedance cardiac output (ICco) measurements and lung fluid content in critically ill patients. Design: Observational study. Setting: Intensive Care Unit of a major teaching hospital in Hong Kong. Patients: Twenty-four critically ill patients who required a pulmonary artery catheter. Measurements and main results: Triplicate thermodilution cardiac output (TDco) and BoMed NCCOM3 (ICco) measurements were made simultaneously on a single occasion in each patient. Lung fluid accumulation was assessed by: (a) thoracic impedance (Zo), (b) radiological assessment of chest X-rays using an alveolar consolidation score (0-4) and (c) scoring the degree of hypoxia and use of positive end-expiratory pressure (PEEP). Offsets (TDco-ICco)/TDco, expressed as percentage, were compared with these indices of excess lung fluid. Patients were divided into those with sepsis (n = 13), fluid balance problems (n = 5) and cardiothoracic problems (n = 6). Mean cardiac output values were: 6.7 1/min TDco (range 3.6-12.9) and 5.2 1/min ICco (range 2.7-9.0). Overall the TDco and ICco values showed great variance, with a bias and limits of agreement of 1.49 +/- 4.16 1/min, or +/- 69 %. In septic patients, increasing offset was correlated with decreases in Zo (r = 0.73, P = 0.005) and increases in alveolar consolidation score (r = 0.72, P = 0.005). Conclusions: The BoMed under-estimates cardiac output in critically ill patients. In septic patients the degree of attenuation of ICco can be related to the extent of lung injury and fluid accumulation within the thorax.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 35 条
[1]
COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[2]
CARDIAC-OUTPUT MEASUREMENT - LACK OF AGREEMENT BETWEEN THERMODILUTION AND THORACIC ELECTRIC BIOIMPEDANCE IN 2 CLINICAL SETTINGS [J].
ATALLAH, MM ;
DEMAIN, AD .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) :182-185
[3]
CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[4]
A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
*BOM LTD, 1991, NCCOM3 R7S CARD MON
[7]
THORACIC ELECTRICAL BIOIMPEDANCE MEASUREMENT OF CARDIAC-OUTPUT - NOT READY FOR PRIME-TIME [J].
CLARKE, DE ;
RAFFIN, TA .
CRITICAL CARE MEDICINE, 1993, 21 (08) :1111-1112
[8]
The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[9]
Impedance cardiography - The impact of new technology [J].
Critchley, LAH .
ANAESTHESIA, 1998, 53 (07) :677-684
[10]
Non-invasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man [J].
Critchley, LAH ;
Conway, F ;
Anderson, PJ ;
Tomlinson, B ;
Critchley, JAJH .
CLINICAL AUTONOMIC RESEARCH, 1997, 7 (02) :97-101