Three dimensional mapping of atrial fibrillation: Techniques and necessity

被引:5
作者
Calkins, H [1 ]
机构
[1] Johns Hopkins Univ Hosp, Baltimore, MD 21287 USA
关键词
atrial fibrillation; catheter ablation; electroanatomic mapping; pulmonary vein stenosis; mapping systems;
D O I
10.1007/s10840-005-2624-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over the past 5 years, catheter ablation of atrial fibrillation (AF) has evolved from an experimental procedure to one that is now performed throughout the world. The rapid and widespread acceptance of this procedure reflects encouraging reports of the safety and efficacy of catheter ablation of AF. The improved outcomes of catheter ablation of AF have resulted from a combination of increasing clinical experience, but also several important technological advances. One of the most important of these has been the development and widespread utilization of three dimensional mapping systems during AF ablation The purpose of this article is to, briefly review the current status and clinical role of three dimensional mapping systems in catheter ablation of AF.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 30 条
  • [1] Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    Chen, SA
    Hsieh, MH
    Tai, CT
    Tsai, CF
    Prakash, VS
    Yu, WC
    Hsu, TL
    Ding, YA
    Chang, MS
    [J]. CIRCULATION, 1999, 100 (18) : 1879 - 1886
  • [2] De Groot NM, 2000, J CARDIOVASC ELECTR, V11, P1183
  • [3] Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation
    Faddis, MN
    Blume, W
    Finney, J
    Hall, A
    Rauch, J
    Sell, J
    Bae, KT
    Talcott, M
    Lindsay, B
    [J]. CIRCULATION, 2002, 106 (23) : 2980 - 2985
  • [4] Gepstein L, 1997, CIRCULATION, V95, P1611
  • [5] Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Takahashi, A
    Hocini, M
    Quiniou, G
    Garrigue, S
    Le Mouroux, A
    Le Métayer, P
    Clémenty, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) : 659 - 666
  • [6] Electrophysiological breakthroughs from the left atrium to the pulmonary veins
    Haïssaguerre, M
    Shah, DC
    Jaïs, P
    Hocini, M
    Yamane, T
    Deisenhofer, I
    Chauvin, M
    Garrigue, S
    Clémenty, J
    [J]. CIRCULATION, 2000, 102 (20) : 2463 - 2465
  • [7] A focal source of atrial fibrillation treated by discrete radiofrequency ablation
    Jais, P
    Haissaguerre, M
    Shah, DC
    Chouairi, S
    Gencel, L
    Hocini, M
    Clementy, J
    [J]. CIRCULATION, 1997, 95 (03) : 572 - 576
  • [8] Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging
    Kato, R
    Lickfett, L
    Meininger, G
    Dickfeld, T
    Wu, R
    Juang, G
    Angkeow, P
    LaCorte, J
    Bluemke, D
    Berger, R
    Halperin, HR
    Calkins, H
    [J]. CIRCULATION, 2003, 107 (15) : 2004 - 2010
  • [9] Time courses and quantitative analysis of atrial fibrillation episode number and duration after circular plus linear left atrial lesions - Trigger elimination or substrate modification: Early or delayed cure?
    Kottkamp, H
    Tanner, H
    Kobza, R
    Schirdewahn, P
    Dorszewski, A
    Gerds-Li, JH
    Carbucicchio, C
    Piorkowski, C
    Hindricks, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) : 869 - 877
  • [10] Efficacy and safety of segmental ostial versus circumferential extra-ostial pulmonary vein isolation for atrial fibrillation
    Mansour, M
    Ruskin, J
    Keane, D
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (05) : 532 - 537