Enhancement of hepatic parenchyma, aorta, and portal vein in helical CT: Comparison of lodixanol and lopromide

被引:12
作者
Graf, O [1 ]
Gazelle, GS [1 ]
Kreuzer, S [1 ]
Halpern, EF [1 ]
Boehm, P [1 ]
Lechner, G [1 ]
Mueller, PR [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,DIV ABDOMINAL IMAGING & INTERVENT RADIOL,BOSTON,MA 02114
关键词
NONIONIC CONTRAST AGENTS; ADVERSE REACTIONS; MEDIA; OSMOLALITY;
D O I
10.2214/ajr.168.1.8976948
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine hepatic, aortic, and portal vein enhancement with a new dimeric, nonionic, isotonic contrast medium (iodixanol) in a routinely performed helical CT protocol and compare enhancement characteristics with those of a monomeric, nonionic, low-osmolality contrast medium (iopromide). SUBJECTS AND METHODS. In 81 patients, we injected 150 mi of iodixanol (320 mg I/ml), iodixanol (300 mg I/ml), or iopromide (300 mg I/ml). Injection rate was 5 ml/sec. A dual-phase helical CT scan was obtained (first helical scan began at 30 sec, second helical scan began at 70 sec), and enhancement characteristics were assessed. Results were analyzed taking into account various intrinsic parameters of patients. RESULTS. During the second imaging phase, iodixanol at 320 mg I/ml and iodixanol at 300 mg I/ml provided significantly higher enhancement of the Liver (75 H, 69 H, 62 H), aorta (144 H, 140 H, 122 H), and portal vein (147 H, 147 H, 118 H) than did iopromide at 300 mg I/ml. No significant differences were observed during the first imaging phase. CONCLUSION. The combination of higher vascular and parenchymal enhancement levels after injection of the isotonic agent may represent a different quality of tissue enhancement. Such an enhancement would be characterized more by a higher contribution of the blood pool compartment to absolute enhancement levels than by a contribution of the interstitial compartment. Further studies are needed to determine whether the use of isotonic agents effects lesion conspicuity.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 13 条
[1]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[2]   HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ .
RADIOLOGY, 1994, 190 (03) :721-725
[3]   OPACIFICATION OF BLOOD-VESSELS AND SOFT-TISSUES AT CT WITH NONIONIC CONTRAST-MEDIA [J].
DAWSON, P ;
BLOMLEY, M .
RADIOLOGY, 1994, 193 (01) :284-285
[4]  
DAWSON P, 1995, RADIOLOGY, V197, P347
[5]   INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS [J].
DODD, GD ;
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :643-645
[6]   Effect of rate of contrast medium injection on hepatic enhancement at CT [J].
Garcia, PA ;
Bonaldi, VM ;
Bret, PM ;
Liang, LJ ;
Reinhold, C ;
Atri, M .
RADIOLOGY, 1996, 199 (01) :185-189
[7]  
Gazelle G S, 1994, Acad Radiol, V1, P373
[8]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[9]   RESULTS OF RANDOMIZED CONTROLLED TRIALS OF LOW-OSMOLALITY VERSUS HIGH-OSMOLALITY CONTRAST-MEDIA [J].
KINNISON, ML ;
POWE, NR ;
STEINBERG, EP .
RADIOLOGY, 1989, 170 (02) :381-389
[10]   FREQUENCY AND DETERMINANTS OF ADVERSE REACTIONS INDUCED BY HIGH-OSMOLALITY CONTRAST-MEDIA [J].
MOORE, RD ;
STEINBERG, EP ;
POWE, NR ;
WHITE, RI ;
BRINKER, JA ;
FISHMAN, EK ;
ZINREICH, SJ ;
SMITH, CR .
RADIOLOGY, 1989, 170 (03) :727-732