HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS

被引:41
作者
CHAMBERS, TP
BARON, RL
LUSH, RM
DODD, GD
MILLER, WJ
机构
[1] UNIV PITTSBURGH,MED CTR,DEPT RADIOL,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,MED CTR,DEPT PHARMACOL,PITTSBURGH,PA 15213
关键词
COMPUTED TOMOGRAPHY (CT); CONTRAST MEDIA; COMPARATIVE STUDIES; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1148/radiology.190.3.8115618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors prospectively compared the effects of ionic and nonionic contrast agents on hepatic enhancement at computed tomography (CT) in the same patient population. MATERIALS AND METHODS: Forty-six patients underwent abdominal CT with either ionic or nonionic contrast agents. At 6-month follow-up, the alternative agent was used. Pre- and postcontrast attenuation values of liver and Vessels were obtained; enhancement and postinjection time of each image were recorded. The area under a computer-generated enhancement-time curve was calculated as a means of measuring enhancement over time. Mean liver enhancement with ionic and nonionic contrast agents was compared. RESULTS: Mean hepatic enhancement with ionic contrast material was greater than with nonionic contrast material at all time intervals through 90 seconds after injection. The difference was statistically significant from 61 to 70 seconds. Mean peak liver enhancement for ionic and nonionic contrast agents was nearly identical (59 and 58 HU, respectively), but mean time to peak hepatic enhancement with nonionic contrast agent was greater by 10 seconds. CONCLUSION: These results indicate that ionic contrast agent may effect greater liver tumor conspicuity.
引用
收藏
页码:721 / 725
页数:5
相关论文
共 11 条
  • [1] COMPARISON OF PRE-CONTRAST AND POST-CONTRAST CT IN HEPATIC MASSES
    BERLAND, LL
    LAWSON, TL
    FOLEY, WD
    MELROSE, BL
    CHINTAPALLI, KN
    TAYLOR, AJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (05) : 853 - 858
  • [2] HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    CONFER, SR
    [J]. RADIOLOGY, 1993, 188 (03) : 627 - 631
  • [3] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [4] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [5] DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS
    HEIKEN, JP
    BRINK, JA
    MCCLENNAN, BL
    SAGEL, SS
    FORMAN, HP
    DICROCE, J
    [J]. RADIOLOGY, 1993, 187 (02) : 327 - 331
  • [6] ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA
    KATAYAMA, H
    YAMAGUCHI, K
    KOZUKA, T
    TAKASHIMA, T
    SEEZ, P
    MATSUURA, K
    [J]. RADIOLOGY, 1990, 175 (03) : 621 - 628
  • [7] DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT
    KORMANO, M
    PARTANEN, K
    SOIMAKALLIO, S
    KIVIMAKI, T
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 364 - 367
  • [8] DYNAMIC CT OF HEPATIC MASSES WITH INTRAVENOUS AND INTRA-ARTERIAL CONTRAST MATERIAL
    MOSS, AA
    DEAN, PB
    AXEL, L
    GOLDBERG, HI
    GLAZER, GM
    FRIEDMAN, MA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (05) : 847 - 852
  • [9] CONTRAST-ENHANCED CT OF THE LIVER AND SPLEEN - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS
    NELSON, RC
    CHEZMAR, JL
    PETERSON, JE
    BERNARDINO, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) : 973 - 976
  • [10] HEPATIC DYNAMIC SEQUENTIAL CT - SECTION ENHANCEMENT PROFILES WITH A BOLUS OF IONIC AND NONIONIC CONTRAST AGENTS
    NELSON, RC
    MOYERS, JH
    CHEZMAR, JL
    HOEL, MJ
    JONES, EC
    PETERSON, JE
    CORK, RD
    BERNARDINO, ME
    [J]. RADIOLOGY, 1991, 178 (02) : 499 - 502