Diurnal variations in human corneal thickness

被引:165
作者
Harper, CL
Boulton, ME
Bennett, D
Marcyniuk, B
JarvisEvans, JH
Tullo, AB
Ridgway, AE
机构
[1] UNIV MANCHESTER, DEPT OPHTHALMOL, MANCHESTER M13 9WH, LANCS, ENGLAND
[2] UNIV MANCHESTER, INST SCI & TECHNOL, MANCHESTER SCH MANAGEMENT, MANCHESTER M60 1QD, LANCS, ENGLAND
[3] MANCHESTER ROYAL EYE HOSP, MANCHESTER M13 9WH, LANCS, ENGLAND
关键词
D O I
10.1136/bjo.80.12.1068
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim - To elucidate the diurnal variation in human corneal thickness over a 48 hour period. Method - Changes in central corneal thickness were monitored in eight healthy subjects (four male, four female) aged between 10 and 63 years using an ultrasonic pachymeter. Measurements were made over a 48 hour period - immediately before sleep, immediately upon waking and at 15, 30, 45 minutes, 1, 1.5, 2, 2.5, 3 hours, and at 2 hour intervals thereafter throughout the remainder of each day. Results - The mean corneal thickness for the group (SD) was 546 (14) mu m, with a mean overnight increase of 5.5% (2.9%) (range 1.9-12.6%) and a maximum diurnal increase of 7.2% (2.8%) (range 2.1-14.3%). Individual differences in the extent of diurnal and overnight variation occurred within the group. For three subjects, the first reading taken on waking was not the highest and corneal thickness continued to increase. Conclusion - These data confirm an increase of corneal thickness during sleep, but also reveal considerable variation during waking hours. Thus, the overnight changes in corneal thickness are not truly representative of diurnal variations in human corneal thickness and, in fact, much greater diurnal variation occurs than the 3.0-4.4% previously reported.
引用
收藏
页码:1068 / 1072
页数:5
相关论文
共 32 条
[1]  
AITKEN M, 1989, STAT MODELLING GLIM
[2]  
Baker R. J, 1985, GLIM 3 77 REFERENCE
[3]   EFFECT OF HUMIDITY ON THE DESWELLING FUNCTION OF THE HUMAN CORNEA [J].
BOURASSA, S ;
BENJAMIN, WJ ;
BOLTZ, RL .
CURRENT EYE RESEARCH, 1991, 10 (06) :493-500
[4]   FORSKOLIN-INDUCED HCO3- CURRENT ACROSS APICAL MEMBRANE OF THE FROG CORNEAL EPITHELIUM [J].
CANDIA, OA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (02) :C215-C233
[5]   POSITIVE CORRELATION OF CORNEAL THICKNESS AND ENDOTHELIAL-CELL LOSS - SERIAL MEASUREMENTS AFTER CATARACT-SURGERY [J].
CHENG, H ;
BATES, AK ;
WOOD, L ;
MCPHERSON, K .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (07) :920-922
[6]  
EFRON N, 1979, INVEST OPHTH VIS SCI, V18, P93
[7]   PROBABILITY PLOT CORRELATION COEFFICIENT TEST FOR NORMALITY [J].
FILLIBEN, JJ .
TECHNOMETRICS, 1975, 17 (01) :111-117
[8]  
FRAMPTON P, 1987, AM J OPTOM PHYS OPT, V64, P54
[9]   BIOMICROSCOPE AND VICKERS IMAGE SPLITTING EYEPIECE APPLIED TO DIURNAL-VARIATION IN HUMAN CENTRAL CORNEAL THICKNESS [J].
GERSTMAN, DR .
JOURNAL OF MICROSCOPY, 1972, 96 (DEC) :385-388
[10]   THICKNESS-HYDRATION RELATIONSHIP OF CORNEA [J].
HEDBYS, BO ;
MISHIMA, S .
EXPERIMENTAL EYE RESEARCH, 1966, 5 (03) :221-&