Metal and biodegradable interference screws: Comparison of failure strength

被引:66
作者
Johnson, LL [1 ]
vanDyk, GE [1 ]
机构
[1] MICHIGAN STATE UNIV,DEPT SURG,E LANSING,MI 48824
来源
ARTHROSCOPY | 1996年 / 12卷 / 04期
关键词
anterior cruciate ligament; fixation; interference screw; biodegradable; bone compaction method;
D O I
10.1016/S0749-8063(96)90039-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this laboratory investigation was to determine if there was any difference in the force required to pull out a patellar bone-tendon-bone graft from a femoral bone tunnel when secured by an interference screw of different materials, metal or biodegradable. The tibial end of the bone-tendon-bone graft was placed in the femoral tunnel. A 9-mm metal interference screw was used on the left side, and a 9-mm biodegradable screw was used on the right to secure the graft. Ultimate load to failure was determined by Instron testing. The average load before failure for the graft secured by the metal screw was 436 Newtons and for the biodegradable screw was 565 Newtons. A statistical significance was not demonstrated because there was wide range of loads between donor specimens, probably because of variations in bone density.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 14 条
[1]  
BACH BR, 1989, AM J KNEE SURG, V2, P76
[2]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[3]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[4]  
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[5]  
JOHNSON LL, 1993, CRUCIAL LIGAMENTS, P555
[6]   PRIMARY STABILITY OF INTERFERENCE SCREW FIXATION - INFLUENCE OF SCREW DIAMETER AND INSERTION TORQUE [J].
KOHN, D ;
ROSE, C .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :334-338
[7]   FIXATION STRENGTH OF A BIODEGRADABLE SCREW IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
KOUSA, P ;
JARVINEN, TLN ;
POHJONEN, T ;
KANNUS, P ;
KOTIKOSKI, M ;
JARVINEN, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (06) :901-905
[8]   A BIOMECHANICAL COMPARISON OF DIFFERENT SURGICAL TECHNIQUES OF GRAFT FIXATION IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
KUROSAKA, M ;
YOSHIYA, S ;
ANDRISH, JT .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (03) :225-229
[9]  
LAMBERT KL, 1983, CLIN ORTHOP RELAT R, V172, P85
[10]  
MATTHEWS L S, 1989, Arthroscopy, V5, P225, DOI 10.1016/0749-8063(89)90177-1