Quantification of aortic elasticity: development and experimental validation of a method using computed tomography

被引:38
作者
Ganten, M
Boese, JM
Leitermann, D
Semmler, W
机构
[1] Deutsch Krebsforschungszentrum, Dept Biophys & Med Radiat Phys, D-69120 Heidelberg, Germany
[2] Univ Heidelberg, Radiol Univ Hosp, Dept Diagnost Radiol, D-69120 Heidelberg, Germany
关键词
aortic elasticity; aortic distensibility; multidetector-row computed tomography; functional imaging of vessel wall;
D O I
10.1007/s00330-005-2857-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Aortic distensibility depending on aortic cross-sectional area changes is an important parameter for the grading of vascular diseases. This study measured aortic area changes by multidetector computed tomography. An image reconstruction algorithm was developed to assess aorta diameter and area as a function of the cardiac cycle with sufficient time resolution along the entire length of the aorta by four-detector row computed tomography. The algorithm was tested on porcine aortic specimens and compared with an optical reference method. The error of the relative vessel area change comparing the two methods was found to be about 3%. Initial tests on patient datasets indicate that clinical application is feasible. The proposed method has the advantage that it can easily be integrated into a modified routine CT angiography study and allows the measurement of aortic cross-sectional area changes.
引用
收藏
页码:2506 / 2512
页数:7
相关论文
共 31 条
[1]
Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance [J].
Abada, HT ;
Sapoval, MR ;
Paul, JF ;
de Maertelaer, V ;
Mousseaux, E ;
Gaux, JC .
EUROPEAN RADIOLOGY, 2003, 13 (12) :2699-2704
[2]
In vivo validation of cardiac spiral computed tomography using retrospective gating [J].
Albers, J ;
Boese, JM ;
Vahl, CF ;
Hagl, S .
ANNALS OF THORACIC SURGERY, 2003, 75 (03) :885-889
[3]
Bahner M. L., 1999, Electromedica, V67, P37
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement [J].
Boese, JM ;
Bock, M ;
Schoenberg, SO ;
Schad, LR .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1703-1713
[6]
Boese JM, 2000, RADIOLOGE, V40, P123, DOI 10.1007/s001170050020
[7]
Boese JM, 2001, RADIOLOGY, V221, P457
[8]
Multidetector-row CT angiography of the infrarenal aortic and lower extremities arterial disease [J].
Catalano, C ;
Napoli, A ;
Fraioli, F ;
Venditti, F ;
Votta, V ;
Passariello, R .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M88-M93
[9]
Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system [J].
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Suess, C ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (10) :2650-2662
[10]
Posttraumatic abdominal aortic dissection [J].
Hahmann, M ;
Richter, GM ;
Schuhmacher, H ;
Allenberg, JR ;
Kauffmann, GW .
RADIOLOGE, 2001, 41 (07) :590-594