An amperometric biosensor for glucose based on electrodeposited redox polymer/glucose oxidase film on a gold electrode

被引:25
作者
Fei, JJ [1 ]
Wu, YH [1 ]
Ji, XB [1 ]
Wang, J [1 ]
Hu, SS [1 ]
Gao, ZQ [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.2116/analsci.19.1259
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we described a glucose biosensor based on the co-electrodeposition of a poly(vinylimidazole) complex of [Os(bpy)(2)Cl](+/2+) (PVI-Os) and glucose oxidase (GOX) on a gold electrode surface. The one-step co-electrodeposition method provided a better control on the sensor construction, especially when it was applied to microsensor construction. The modified electrode exhibited the classical features of a kinetically fast redox couple bound to an electrode surface and the redox potential of the redox polymer/enzyme film was 0.14 V (vs. SCE). For a scan rate of up to 200 mV s(-1), the peak-to-peak potential separation was less than 25 mV. In the presence of glucose, a typical catalytic oxidation current was observed, which reached a plateau at 0.25 V (vs. SCE). Under the optimal experimental conditions, the steady-state electrooxidation current measured at 0.30 V (vs. SCE) was linear to the glucose concentration in the range of 0 - 30 mM. Successful attempts were made in blood sample analysis.
引用
收藏
页码:1259 / 1263
页数:5
相关论文
共 29 条
[1]   INTRAMOLECULAR ELECTRON-TRANSFER RATES IN FERROCENE-DERIVATIZED GLUCOSE-OXIDASE [J].
BADIA, A ;
CARLINI, R ;
FERNANDEZ, A ;
BATTAGLINI, F ;
MIKKELSEN, SR ;
ENGLISH, AM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) :7053-7060
[2]   Electrochemical sensors [J].
Bakker, E ;
Telting-Diaz, M .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2781-2800
[3]   Modification of glucose oxidase by the covalent attachment of a tetrathiafulvalene derivative [J].
Bartlett, PN ;
Booth, S ;
Caruana, DJ ;
Kilburn, JD ;
Santamaria, C .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :734-742
[4]   MODIFICATION OF GLUCOSE-OXIDASE BY TETRATHIAFULVALENE [J].
BARTLETT, PN ;
BRADFORD, VQ .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1990, (16) :1135-1136
[5]   PULSED AMPEROMETRIC DETECTION OF GLUCOSE IN BIOLOGICAL-FLUIDS AT A SURFACE-MODIFIED GOLD ELECTRODE [J].
BINDRA, DS ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2566-2570
[6]   MASS-TRANSPORT AND REACTION KINETIC-PARAMETERS DETERMINED ELECTROCHEMICALLY FOR IMMOBILIZED GLUCOSE-OXIDASE [J].
CASTNER, JF ;
WINGARD, LB .
BIOCHEMISTRY, 1984, 23 (10) :2203-2210
[7]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[8]  
CSOREGI E, 1995, ANAL CHEM, V67, P1240
[9]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131
[10]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358