摘要
In this paper, we described a glucose biosensor based on the co-electrodeposition of a poly(vinylimidazole) complex of [Os(bpy)(2)Cl](+/2+) (PVI-Os) and glucose oxidase (GOX) on a gold electrode surface. The one-step co-electrodeposition method provided a better control on the sensor construction, especially when it was applied to microsensor construction. The modified electrode exhibited the classical features of a kinetically fast redox couple bound to an electrode surface and the redox potential of the redox polymer/enzyme film was 0.14 V (vs. SCE). For a scan rate of up to 200 mV s(-1), the peak-to-peak potential separation was less than 25 mV. In the presence of glucose, a typical catalytic oxidation current was observed, which reached a plateau at 0.25 V (vs. SCE). Under the optimal experimental conditions, the steady-state electrooxidation current measured at 0.30 V (vs. SCE) was linear to the glucose concentration in the range of 0 - 30 mM. Successful attempts were made in blood sample analysis.
引用
收藏
页码:1259 / 1263
页数:5
相关论文
共 29 条
[21]   Electrochemical glucose and lactate sensors based on ''wired'' thermostable soybean peroxidase operating continuously and stably at 37 degrees C [J].
Kenausis, G ;
Chen, Q ;
Heller, A .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1054-1060
[22]  
Lay P. A., 1986, Inorg. Synth, V24, P291, DOI [10.1002/9780470132555.ch78, DOI 10.1002/9780470132555.CH78]
[23]  
LIU HY, 1995, ANAL CHIM ACTA, V300, P65
[24]  
MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
[25]   WIRED ENZYME ELECTRODES FOR AMPEROMETRIC DETERMINATION OF GLUCOSE OR LACTATE IN THE PRESENCE OF INTERFERING SUBSTANCES [J].
OHARA, TJ ;
RAJAGOPALAN, R ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2451-2457
[26]   GLUCOSE ELECTRODES BASED ON CROSS-LINKED [OS(BPY)(2)](+/2+) COMPLEXED POLY(L-VINYLIMIDAZOLE) FILMS [J].
OHARA, TJ ;
RAJAGOPALAN, R ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3512-3517
[27]   Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration [J].
Schmidtke, DW ;
Heller, A .
ANALYTICAL CHEMISTRY, 1998, 70 (10) :2149-2155
[28]   Electrochemical sensor arrays [J].
Stefan, RI ;
van Staden, JF ;
Aboul-Enein, HY .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (02) :133-153
[29]   Enzyme based biosensors for in vivo measurements [J].
Wilson, GS ;
Hu, YB .
CHEMICAL REVIEWS, 2000, 100 (07) :2693-2704