Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration

被引:55
作者
Schmidtke, DW [1 ]
Heller, A [1 ]
机构
[1] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
关键词
D O I
10.1021/ac970932u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The hypothesis of the feasibility of one-point in vivo calibration of intravenously implanted glucose sensors during periods of rapid rise and decline of venous blood glucose concentration was tested, Miniature (5 x 10(-4) cm(2) mass transporting area) glucose electrodes with 10-90% response times <2 min, that did not consume oxygen, were implanted in jugular veins of systemically heparinized rats and used in 4-h experiments, during which the blood glucose concentration was amperometrically monitored. The glucose electrodes were made by electrically connecting ("wiring") reaction centers of glucose oxidase through an electron-conducting redox hydrogel to gold electrode surfaces. The redox polymer and enzyme constituting the electrode sensing layer were immobilized by cross-linking, and thus the electrodes had no diffusional and readily leached redox mediator. One hour after their implantation, the electrodes accurately tracked the blood glucose concentration when calibrated in vivo by a one-point calibration, when the glucose concentration was steady, when rising rapidly, and when declining steeply. For an assumed 2-min lag time, the sensor readings were well correlated with the true blood glucose concentrations, with linear regression analysis yielding a slope of 0.97 +/- 0.07 and an intercept (bias) of 0.3 +/- 0.3 mM. The correlation coefficient, r(2), was 0.949 +/- 0.020, and the percent difference through the 2-22 mM range was 1.9 +/- 1.0%. The results suggest that, in combination with understanding and modeling of transient physiological differences between the subcutaneous and the blood glucose concentrations, it will be possible to calibrate by one-point in vivo calibration subcutaneously implanted sensors, even while the glucose concentration changes rapidly.
引用
收藏
页码:2149 / 2155
页数:7
相关论文
共 48 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   Non-invasive glucose monitoring [J].
Arnold, MA .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :46-49
[3]   Short-term canine implantation of a glucose monitoring-telemetry device [J].
Atanasov, P ;
Yang, S ;
Salehi, C ;
Ghindilis, AL ;
Wilkins, E .
MEDICAL ENGINEERING & PHYSICS, 1996, 18 (08) :632-640
[4]  
BERGER AJ, 1997, SPECTROCHIM ACTA A, V53, P282
[5]   LIFE-SPAN OF SUBCUTANEOUS GLUCOSE SENSORS AND THEIR PERFORMANCES DURING DYNAMIC GLYCEMIA CHANGES IN RATS [J].
BOBBIONIHARSCH, E ;
ROHNERJEANRENAUD, F ;
KOUDELKA, M ;
DEROOIJ, N ;
JEANRENAUD, B .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (06) :457-463
[6]   MICRODIALYSIS MEASUREMENT OF THE ABSOLUTE GLUCOSE-CONCENTRATION IN SUBCUTANEOUS ADIPOSE-TISSUE ALLOWING GLUCOSE MONITORING IN DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
DIABETOLOGIA, 1992, 35 (12) :1177-1180
[7]   Correlation between blood glucose concentration in diabetics and noninvasively measured tissue optical scattering coefficient [J].
Bruulsema, JT ;
Hayward, JE ;
Farrell, TJ ;
Patterson, MS ;
Heinemann, L ;
Berger, M ;
Koschinsky, T ;
SandahlChristiansen, J ;
Orskov, H .
OPTICS LETTERS, 1997, 22 (03) :190-192
[8]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[9]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[10]   NEEDLE ENZYME ELECTRODES FOR BIOLOGICAL STUDIES [J].
CHURCHOUSE, SJ ;
BATTERSBY, CM ;
MULLEN, WH ;
VADGAMA, PM .
BIOSENSORS, 1986, 2 (06) :325-342