Electrochemical glucose and lactate sensors based on ''wired'' thermostable soybean peroxidase operating continuously and stably at 37 degrees C

被引:99
作者
Kenausis, G [1 ]
Chen, Q [1 ]
Heller, A [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
D O I
10.1021/ac961083y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Following a recent report from our laboratory on a thermostable amperometric H2O2 sensor based on ''wiring'' soybean peroxidase, glucose and lactate sensors maintaining stable output under continuous operation at 37 degrees C for 12 and 8 days, respectively, were built. The vitreous carbon base of the sensor was coated with four polymer layers. The first was made by cross-linking thermostable soybean peroxidase and the redox polymer formed through complexing part of the rings of poly(vinylpyridine) with [Os(bpy)(2)Cl](+/2+) (bpy = bipyridine) and quaternizing part of the rings with bromoethylamine, The second was an insulating and H2O2 transport controlling cellulose acetate layer, The third was an immobilized glucose oxidase or lactate oxidase layer, The fourth was a substrate transport controlling cellulose acetate layer In the case of the glucose sensor, the current output was independent of potential between -0.2 and +0.3 V (vs SCE), and the response time (t(10/90))was <2 min when the concentration was raised from 0 to 5 mM glucose. The current was independent of the O-2 partial pressure above 15 Torr. The sensor was relatively insensitive to motion and to interferants, Changing the rotation speed of the electrode from 50 to 2500 rpm increased the current by <10%, At a glucose concentration of 4 mM, the addition of 0.1 mM ascorbate decreased the current by <1%. The operational stability was glucose oxidase loading dependent. Though the current decreased by 85% after 100 h of operation at 37 degrees C when the 3-mm-diameter electrode was loaded with only 1.3 mu g of glucose oxidase, it decreased by <1% after such operation when loaded with 52 mu g of the enzyme. Similar results were obtained for the lactate sensor, with the exception of a more noticeable oxygen concentration dependence of the lactate response at low oxygen concentrations.
引用
收藏
页码:1054 / 1060
页数:7
相关论文
共 32 条
[1]   ELECTROCHEMICAL PROBING OF THE ACTIVITY OF GLUCOSE-OXIDASE EMBEDDED SOL-GEL MATRICES [J].
AUDEBERT, P ;
DEMAILLE, C ;
SANCHEZ, C .
CHEMISTRY OF MATERIALS, 1993, 5 (07) :911-913
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .6. MICROELECTRODES FOR THE DETECTION OF L-LACTATE BASED ON FLAVOCYTOCHROME B(2) IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1994, 119 (02) :175-180
[3]  
BLEADEL WJ, 1976, ANAL CHEM, V48, P1240
[4]  
CSOREGI E, 1995, ANAL CHEM, V67, P1240
[5]   SYNTHESIS OF PROTEIN-DOPED SOL-GEL SIO2 THIN-FILMS - EVIDENCE FOR ROTATIONAL MOBILITY OF ENCAPSULATED CYTOCHROME-C [J].
DAVE, BC ;
SOYEZ, H ;
MILLER, JM ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
CHEMISTRY OF MATERIALS, 1995, 7 (08) :1431-1434
[6]   ELECTROPOLYMERIZED O-PHENYLENEDIAMINE FILM AS MEANS OF IMMOBILISING LACTATE OXIDASE FOR A L-LACTATE BIOSENSOR [J].
DEMPSEY, E ;
WANG, J ;
SMYTH, MR .
TALANTA, 1993, 40 (03) :445-451
[7]   Performance of glucose biosensor based on oxygen electrode in physiological fluids and at body temperature [J].
Gamburzev, S ;
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (03) :179-183
[8]  
Ghobadi S., 1996, CURRENT SEPARATIONS, V14, P94
[9]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[10]   Amperometric biosensors [J].
Heller, A .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :50-54