Monte Carlo-based lung cancer treatment planning incorporating PET-defined target volumes

被引:8
作者
Chetty, Indrin J. [1 ]
Fernando, Shaneli [1 ]
Kessler, Marc L. [1 ]
Mcshan, Daniel L. [1 ]
Brooks, Cassandra [1 ]
Haken, Randall K. Ten [1 ]
Kong, Feng-Ming Spring [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2005年 / 6卷 / 04期
关键词
PET imaging; lung cancer; Monte Carlo; target segmentation;
D O I
10.1120/jacmp.2026.25363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite the well-known benefits of positron emission tomography (PET) imaging in lung cancer diagnosis and staging, the poor spatial resolution of PET has limited its use in radiotherapy planning. Methods used for segmenting tumor from normal tissue, such as threshold boundaries using a fraction of the standardized uptake value (SUV), are subject to uncertainties. The issue of respiratory motion in the thorax confounds the problem of accurate target definition. In this work, we evaluate how changing the PET-defined target volume by varying the threshold value in the segmentation process impacts target and normal lung tissue doses. For each of eight lung cancer patients we retrospectively generated multiple PET-target volumes; each target volume corresponds to those voxels with intensities above a given threshold level, defined by a percentage of the maximum voxel intensity. PET-defined targets were compared to those from CT; CT targets comprise a composite volume generated from breath-hold inhale and exhale datasets; the CT dataset therefore also includes the extents of tumor motion. Treatment plans using Monte Carlo dose calculation were generated for all targets; the dose uniformity was approximately 100 +/- 5% within the internal target volume (ITV) ( formed by a uniform 8-mm expansion of the composite gross target volume (GTV)). In all cases differences were observed in the generalized equivalent uniform doses (gEUDs) to the targets and in the mean lung doses (MLDs) and normal tissue complication probabilities (NTCPs) to the normal lung tissues. The magnitudes of the dose differences were found to depend on the target volume, location, and amount of irradiated normal lung tissue, and in many instances were clinically meaningful ( greater than a single 2 Gy fraction). For those patients studied, results indicate that accurate dosimetry using PET volumes is highly dependent on accurate target segmentation. Further study with correlation to clinical outcome will be helpful in determining how to apply these various PET and CT volumes in treatment planning, to potentially improve local tumor control and reduce normal tissue toxicities.
引用
收藏
页码:65 / 76
页数:12
相关论文
共 28 条
[1]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[2]   Impact of positron emission tomography on the management of patients with small-cell lung cancer - Preliminary experience [J].
Blum, R ;
MacManus, MP ;
Rischin, D ;
Michael, M ;
Ball, D ;
Hicks, RJ .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2004, 27 (02) :164-171
[3]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[4]   Automated generation of a four-dimensional model of the liver using warping and mutual information [J].
Brock, KM ;
Balter, JM ;
Dawson, LA ;
Kessler, ML ;
Meyer, CR .
MEDICAL PHYSICS, 2003, 30 (06) :1128-1133
[5]   Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET [J].
Caldwell, CB ;
Mah, K ;
Skinner, M ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1381-1393
[6]   Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT:: The impact of 18FDG-hybrid PET fusion [J].
Caldwell, CB ;
Mah, K ;
Ung, YC ;
Danjoux, CE ;
Balogh, JM ;
Ganguli, SN ;
Ehrlich, LE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :923-931
[7]   Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media [J].
Chetty, IJ ;
Charland, PM ;
Tyagi, N ;
McShan, DL ;
Fraass, BA ;
Bielajew, AF .
MEDICAL PHYSICS, 2003, 30 (04) :563-573
[8]   Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions [J].
Das, SK ;
Miften, MM ;
Zhou, S ;
Bell, M ;
Munley, MT ;
Whiddon, CS ;
Craciunescu, O ;
Baydush, AH ;
Wong, T ;
Rosenman, JG ;
Dewhirst, MW ;
Marks, LB .
MEDICAL PHYSICS, 2004, 31 (06) :1452-1461
[9]  
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.3.CO
[10]  
2-B