Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET

被引:130
作者
Caldwell, CB
Mah, K
Skinner, M
Danjoux, CE
机构
[1] Sunnybrook & Womens Coll Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[4] Toronto Sunnybrook Reg Canc Ctr, Toronto, ON, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 05期
关键词
tumor motion; PET; CT simulation; PTV; ITV;
D O I
10.1016/S0360-3016(02)04609-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To characterize the limitations of fast, spiral computed tomography (CT) when imaging a moving object and to investigate whether positron emission tomography (PET) can predict the internal target volume ITV) and ultimately improve the planning target volume (PTV) for moving tumors. Methods and Materials: To mimic tumors, three fillable spheres were imaged while both stationary and during periodic motion using spiral CT and PET. CT- and PET-imaged volumes were defined quantitatively using voxel values. Ideal PTVs for each scenario were calculated. CT-based PTVs were generated using margins of 7.5, 10, and 15 mm to account for both organ motion and setup uncertainties. PET-based PTVs were derived with the assumption that motion was captured in the PET images and only a margin (7.5 mm) for setup errors was necessary. Comparisons between CT-based and PET-based PTVs with ideal PTVs were performed. Results: CT imaging of moving spheres resulted in significant distortions in the three-dimensional (3D) image-based representations, and did not, in general, result in images well representative of either moving or stationary spheres. PET images were similar to the ideal capsular shape encompassing the sphere and its motion. In all cases, CT-imaged volumes were larger than that for the stationary sphere (range of excess volume from 0.4 to 29 cm(3) for stationary volumes of 2.14 to 172 cm(3)), but smaller than that for the true motion volume. PET-imaged volumes were larger than the true motion volume (difference from ideal ranged from 3 to 94 cm(3) for motion volumes of 1.2 to 243 cm(3)) and much larger than the stationary volume. Using CT data, geographic miss of some part of the ideal PTV occurred for 0 of 24 cases, 11 of 24 cases, and 18 of 24 cases using a 15-mm, 10-mm, and 7.5-mm margin, respectively. Geographic miss did not occur in any case for the PET-based PTV. The amount of normal tissue" included in CT-based PTVs was dramatically greater than that included in PET-based PTVs. Conclusion: Fast CT imaging of a moving tumor can result in poor representation of the time-averaged position and shape of the tumor. PET imaging can provide a more accurate representation of the 3D volume encompassing motion of model tumors and has potential to provide patient-specific motion volumes for an individualized ITV. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:1381 / 1393
页数:13
相关论文
共 28 条
[1]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[2]   Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT:: The impact of 18FDG-hybrid PET fusion [J].
Caldwell, CB ;
Mah, K ;
Ung, YC ;
Danjoux, CE ;
Balogh, JM ;
Ganguli, SN ;
Ehrlich, LE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :923-931
[3]   Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients [J].
Chen, QS ;
Weinhous, MS ;
Deibel, FC ;
Ciezki, JP ;
Macklis, RM .
MEDICAL PHYSICS, 2001, 28 (09) :1850-1856
[4]   What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? [J].
Ekberg, L ;
Holmberg, O ;
Wittgren, L ;
Bjelkengren, G ;
Landberg, T .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) :71-77
[5]  
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.0.CO
[6]  
2-F
[7]   Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation [J].
Hanley, J ;
Debois, MM ;
Mah, D ;
Mageras, GS ;
Raben, A ;
Rosenzweig, K ;
Mychalczak, B ;
Schwartz, LH ;
Gloeggler, PJ ;
Lutz, W ;
Ling, CC ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :603-611
[8]  
International Commission in Radiation Units and Measurements, 1993, 50 ICRU
[9]  
International Commission on Radiation Units and Measurements, 1999, 50 ICRU
[10]   Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: A feasibility study [J].
Kim, DJW ;
Murray, BR ;
Halperin, R ;
Roa, WHY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01) :43-49