Mobile and fixed bearing total knee prosthesis functional comparison during stair climbing

被引:52
作者
Catani, F
Benedetti, MG
De Felice, R
Buzzi, R
Giannini, S
Aglietti, P
机构
[1] Univ Bologna, Gait Anal Lab, Dept Orthopaed Surg, Ist Ortoped Rizzoli, I-40136 Bologna, Italy
[2] Univ Florence, Dept Orthopaed Surg, Ctr Traumatol Ortoped, Florence, Italy
关键词
total knee replacement; gait analysis; knee biomechanics; stair climbing; electromyography;
D O I
10.1016/S0268-0033(03)00044-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this investigation is to determine the functional performance of the mobile bearing total knee replacement prosthesis as compared to the fixed bearing type total knee replacement prosthesis. Design. Kinematics, kinetics, and electromyography data were gained from 10 patients with mobile bearing and 10 patients with a fixed bearing posterior stabilized Insall Burstein II total knee replacement during ascending and descending stairs. A control group of 10 normal subjects, matched by sex and age, was also analysed. Background. No significant biomechanical differences in patients with different total knee replacement designs have been reported from level-walking studies. Slightly better performance of posterior retaining with respect to cruciate sacrificing total knee replacement designs have been claimed from stair climbing studies. Only one study has been conducted regarding mobile versus fixed bearing total knee replacement assessed by gait analysis. This study did not show any biomechanical differences between the two groups. Methods. Motion analysis was used to quantify the knee kinematics, kinetics, and electromyography (right and left longissimus dorsi, gluteus medius, rectus femoris, biceps femoris, semitendinosus, gastrocnemius and tibialis anterior muscles) during stair ascent and descent. Results. The mobile bearing group demonstrated a reduced knee extensor moment during stair climbing and descending, and a reduced knee adductor moment during stair climbing. When ascending stairs, most of the mobile bearing patients show a peak knee flexion and a peak knee flexion moment at the late stance phase during the double support period. This kinematic and kinetic pattern is absent in normal subject. Both mobile bearing and fixed bearing groups showed abnormal electromyography patterns in both descending and ascending. Conclusions. During stair climbing, the mobile bearing design demonstrates a different kinematic pattern to the fixed bearing total knee replacement. Lower limb compensatory mechanisms seemed to be adopted particularly by the mobile bearing patients during ascending stairs.
引用
收藏
页码:410 / 418
页数:9
相关论文
共 27 条
[1]  
Andriacchi T P, 1997, Am J Knee Surg, V10, P255
[2]  
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[3]   Patellofemoral design influences function following total knee arthroplasty [J].
Andriacchi, TP ;
Yoder, D ;
Conley, A ;
Rosenberg, A ;
Sum, J ;
Galante, JO .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :243-249
[4]   THE INFLUENCE OF TOTAL KNEE-REPLACEMENT DESIGN ON WALKING AND STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
FERMIER, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1328-1335
[5]  
Banks S A, 1997, Am J Knee Surg, V10, P261
[6]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[7]   Data management in gait analysis for clinical applications [J].
Benedetti, MG ;
Catani, F ;
Leardini, A ;
Pignotti, E ;
Giannini, S .
CLINICAL BIOMECHANICS, 1998, 13 (03) :204-215
[8]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[9]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[10]   BIOMECHANICAL GAIT EVALUATION OF PRE AND POSTOPERATIVE TOTAL KNEE REPLACEMENT PATIENTS [J].
CHAO, EY ;
LAUGHMAN, RK ;
STAUFFER, RN .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1980, 97 (04) :309-317