Improvements in quantitative chiral determinations using the mass spectrometric kinetic method

被引:28
作者
Young, Brandy L. [1 ]
Cooks, R. Graham [1 ]
机构
[1] Purdue Univ, Dept Chem, Astron Lab Mass Spectometry, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
chiral analysis; kinetic method; tandem mass spectrometry; cluster ions; chiral chromatography;
D O I
10.1016/j.ijms.2007.02.036
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A significant shortcoming of the kinetic method for determining chiral purity from the competitive dissociation of a metal complex chelated with a chiral analyte and chiral reference is that it does not give useful quantitative data for high purity chiral samples in, comparison to the standard chiral chromatography techniques. To extend the range of applications of the kinetic method to high chiral purity samples, a "vernier" method is reported which gives more accurate quantitative data for samples covering a narrow range of chiral purity. This is demonstrated for the case of a model amino acid in which Ni-II is used as the metal cation, asparagine as the chiral reference, and the analyte is tryptophan. By selecting experimental conditions to give a measured peak abundance ratio near unity for the two competitive fragments (where abundance ratios are more accurately measured than at higher or lower values), samples of high (90-100%) chiral purity were more accurately assayed in the experiment using pure tryptophan. By switching the chirality of the reference compound, samples in the low (0-10%) chiral purity range could also be more precisely measured. The quantitative improvement in accuracy of the chiral measurement is shown by the average accuracy of 0.51% deviation (for the 90-100% chiral purity range of tryptophan using L-Asn as chiral reference) in comparison to the average deviation of 104.1% in the non-vernier region (the region that falls outside the high accuracy region of interest). (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 54 条
[1]   EMDee: An enzymatic method for determining enantiomeric excess [J].
Abato, P ;
Seto, CT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (37) :9206-9207
[2]  
Beesley T. E., 1998, SEPAR SCI S
[3]   Determination of enantiomeric composition by negative-ion electrospray ionization-mass spectrometry using deprotonated N-(3,5-dinitrobenzoyl)amino acids as chiral selectors [J].
Brewer, BN ;
Zu, CL ;
Koscho, ME .
CHIRALITY, 2005, 17 (08) :456-463
[4]   Electrospray ionization tandem mass spectrometry in high-throughput screening of homogeneous catalysts [J].
Chen, P .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2003, 42 (25) :2832-2847
[5]   Kinetic method of making thermochemical determinations: Advances and applications [J].
Cooks, RG ;
Wong, PSH .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (07) :379-386
[6]  
COOKS RG, 1994, MASS SPECTROM REV, V13, P287
[7]   CHIRAL RECOGNITION IN THE GAS-PHASE - MASS-SPECTROMETRIC STUDIES OF DIASTEREOMERIC COBALT COMPLEXES [J].
DANG, TT ;
PEDERSEN, SF ;
LEARY, JA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (05) :452-459
[8]   A VIVID MODEL ILLUSTRATING CHIRAL RECOGNITION INDUCED BY ACHIRAL STRUCTURES [J].
DAVANKOV, VA ;
MEYER, VR ;
RAIS, M .
CHIRALITY, 1990, 2 (04) :208-210
[9]  
Davankov VA, 1997, CHIRALITY, V9, P99, DOI 10.1002/(SICI)1520-636X(1997)9:2<99::AID-CHIR3>3.0.CO
[10]  
2-B