Nonaqueous CE using contactless conductivity detection and ionic liquids as BGEs in ACN

被引:22
作者
Borissova, Maria [1 ]
Gorbatsova, Jelena [1 ]
Ebber, Arkadi [1 ]
Kaljurand, Mihkel [1 ]
Koel, Mihkel [1 ]
Vaher, Merike [1 ]
机构
[1] Tallinn Univ Technol, Dept Chem, EE-12618 Tallinn, Estonia
关键词
contactless conductivity detection; ionic liquids; nonaclueous CE;
D O I
10.1002/elps.200700067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
N,N'-Alkylmethylimidazolium cations have been separated in NACE when one of the N,N'-dialkylimidazolium salts (ionic liquids (ILs)) was used as an electrolyte additive to the organic solvent separation medium. The separated species were 1-methyl-, 1-ethyl-, 1-butyl-, 1-octyl-, 1-decyl-3-methylimidazolium and N-butyl-3-methylpyridinium cations and BGE composed of 1-ethyl-3-methylimidazolium ethylsulfate or 1-butyl-3-methylimidazolium trifluoroacetate [BMIm][FAcO] (A6; B2) diluted in ACN. It was demonstrated that contactless conductivity detection (CCD) may be applied to monitoring the separation process in nonaqueous separation media, allowing to use the UV light-absorbing imidazolium-based electrolyte additives. There could be marked three concentration regions of added ILs; at first ionic strength of BGE below 1-2 mM, and then the actual electrophoretic mobility of analytes rises from 0. At concentrations above 1-2 mM, the added IL facilitated separation. In concentration region of 1-20 mM, the actual electrophoretic mobility of analyzed imidazolium cations was increasing with decrease in separation medium ionic strength. At higher concentrations of BGE (above 30 mM), the conductivity of the separation media became too high for this detector. Some organic dyes were also successfully separated and detected by contactless conductivity detector in a 20 mM A6 separation electrolyte in ACN.
引用
收藏
页码:3600 / 3605
页数:6
相关论文
共 28 条
[1]   Hydrophobic, highly conductive ambient-temperature molten salts [J].
Bonhote, P ;
Dias, AP ;
Papageorgiou, N ;
Kalyanasundaram, K ;
Gratzel, M .
INORGANIC CHEMISTRY, 1996, 35 (05) :1168-1178
[2]   New integrated measurement protocol using capillary electrophoresis instrumentation for the determination of viscosity, conductivity and absorbance of ionic liquid-molecular solvent mixtures [J].
François, Y ;
Zhang, K ;
Varenne, A ;
Gareil, P .
ANALYTICA CHIMICA ACTA, 2006, 562 (02) :164-170
[3]   Conductivity detection for conventional and miniaturised capillary electrophoresis systems [J].
Guijt, RM ;
Evenhuis, CJ ;
Macka, M ;
Haddad, PR .
ELECTROPHORESIS, 2004, 25 (23-24) :4032-4057
[4]   Dynamically coating the capillary with 1-alkyl-3-methylimidazolium-based ionic liquids for separation of basic proteins by capillary electrophoresis [J].
Jiang, TF ;
Gu, YL ;
Liang, B ;
Li, JB ;
Shi, YP ;
Ou, QY .
ANALYTICA CHIMICA ACTA, 2003, 479 (02) :249-254
[5]   Theoretical and empirical approaches to express the mobility of small ions in capillary electrophoresis [J].
Jouyban, A ;
Kenndler, E .
ELECTROPHORESIS, 2006, 27 (5-6) :992-1005
[6]   Miniaturized movable contactless conductivity detection cell for capillary electrophoresis [J].
Macka, M ;
Hutchinson, J ;
Zemann, A ;
Zhang, SS ;
Haddad, PR .
ELECTROPHORESIS, 2003, 24 (12-13) :2144-2149
[7]   Capillary electrophoretic of cationic constituents of imidazolium ionic liquids [J].
Markuszewski, MJ ;
Stepnowski, P ;
Marszall, MP .
ELECTROPHORESIS, 2004, 25 (20) :3450-3454
[8]   Propylene carbonate as a nonaqueous solvent for capillary electrophoresis: Mobility and ionization constant of aliphatic amines [J].
Muzikar, J ;
van de Goor, T ;
Gas, B ;
Kenndler, E .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :428-433
[9]   Formamide as solvent for capillary zone electrophoresis [J].
Porras, SP ;
Kenndler, E .
ELECTROPHORESIS, 2004, 25 (17) :2946-2958
[10]   The principles of migration and dispersion in capillary zone electrophoresis in nonaqueous solvents [J].
Porras, SP ;
Riekkola, ML ;
Kenndler, E .
ELECTROPHORESIS, 2003, 24 (10) :1485-1498