Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters

被引:152
作者
Aguilera-Herrador, Eva [1 ]
Lucena, Rafael [1 ]
Cardenas, Soledad [1 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
ionic liquids; liquid phase microextraction; headspace single-drop microextraction; gas chromatography; mass spectrometry; BTEX; water;
D O I
10.1016/j.chroma.2008.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L-1 (obtained for benzene) and 91 ng L-1 (for o-xylene). The repeatability of the proposed method, expressed as RSD (n = 5), varied between 3.0% (o-xylene) and 5.2% (toluene). (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 31 条
[1]
Direct coupling of ionic liquid based single-drop microextraction and GC/MS [J].
Aguilera-Heirador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
ANALYTICAL CHEMISTRY, 2008, 80 (03) :793-800
[2]
Water solubilization of ethanol and BTEX from gasoline: on-line monitoring by membrane introduction mass spectrometry [J].
Alberici, RM ;
Zampronio, CG ;
Poppi, RJ ;
Eberlin, MN .
ANALYST, 2002, 127 (02) :230-234
[3]
Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[4]
Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography-flame ionization detection [J].
Arambarri, I ;
Lasa, M ;
Garcia, R ;
Millán, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :193-203
[5]
Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction [J].
Ezquerro, O ;
Ortiz, G ;
Pons, B ;
Tena, MT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (01) :17-22
[6]
Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[7]
Room temperature ionic liquids as novel media for 'clean' liquid-liquid extraction [J].
Huddleston, JG ;
Willauer, HD ;
Swatloski, RP ;
Visser, AE ;
Rogers, RD .
CHEMICAL COMMUNICATIONS, 1998, (16) :1765-1766
[8]
Irwin R.J., 1997, ENV CONTAMINANTS ENC
[9]
Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[10]
Thermal stability of low temperature ionic liquids revisited [J].
Kosmulski, M ;
Gustafsson, J ;
Rosenholm, JB .
THERMOCHIMICA ACTA, 2004, 412 (1-2) :47-53