Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers

被引:81
作者
Alvarez, David A. [1 ]
Cranor, Walter L. [1 ]
Perkins, Stephanie D. [1 ]
Clark, Randal C. [1 ]
Smith, Steven B. [2 ]
机构
[1] US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
[2] US Geol Survey, Natl Ctr, Reston, VA 20192 USA
关键词
D O I
10.2134/jeq2006.0463
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response.
引用
收藏
页码:1024 / 1033
页数:10
相关论文
共 34 条
  • [1] Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream
    Alvarez, DA
    Stackelberg, PE
    Petty, JD
    Huckins, JN
    Furlong, ET
    Zaugg, SD
    Meyer, MT
    [J]. CHEMOSPHERE, 2005, 61 (05) : 610 - 622
  • [2] Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments
    Alvarez, DA
    Petty, JD
    Huckins, JN
    Jones-Lepp, TL
    Getting, DT
    Goddard, JP
    Manahan, SE
    [J]. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2004, 23 (07) : 1640 - 1648
  • [3] Alvarez DA, 2007, COMP ANAL C, V48, P171, DOI 10.1016/S0166-526X(06)48008-9
  • [4] Sampling of polar pesticides from water matrices
    Barcelo, D
    Hennion, MC
    [J]. ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) : 3 - 18
  • [5] Temperature-dependent uptake rates of nonpolar organic compounds by semipermeable membrane devices and low-density polyethylene membranes
    Booij, K
    Hofmans, HE
    Fischer, CV
    Van Weerlee, EM
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (02) : 361 - 366
  • [6] Pharmaceuticals and personal care products in the environment: Agents of subtle change?
    Daughton, CG
    Ternes, TA
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 : 907 - 938
  • [7] Quality control associated with use of semipermeable membrane devices
    DeVita, WM
    Crunkilton, RL
    [J]. ENVIRONMENTAL TOXICOLOGY AND RISK ASSESSMENT: SEVENTH VOLUME, 1998, 1333 : 237 - 245
  • [8] Application of semipermeable membrane device for assessing toxicity in drinking water
    Gilli, G
    Schilirò, T
    Pignata, C
    Traversi, D
    Carraro, E
    Baiocchi, C
    Aigotti, R
    Giacosa, D
    Fea, E
    [J]. CHEMOSPHERE, 2005, 61 (11) : 1691 - 1699
  • [9] Huckins J.N., 2006, MONITORS ORGANIC CHE
  • [10] Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices
    Huckins, JN
    Petty, JD
    Lebo, JA
    Almeida, FV
    Booij, K
    Alvarez, DA
    Clark, RC
    Mogensen, BB
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (01) : 85 - 91