In vivo 1H NMR spectroscopy of the human brain at 7 T

被引:312
作者
Tkác, I [1 ]
Andersen, P [1 ]
Adriany, G [1 ]
Merkle, H [1 ]
Ugurbil, K [1 ]
Gruetter, R [1 ]
机构
[1] Univ Minnesota, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
H-1 NMR spectroscopy; high magnetic field; resolution; human brain;
D O I
10.1002/mrm.1213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo H-1 NMR spectra from the human brain were measured at 7 T. Ultrashort echo-time STEAM was used to minimize)modulation and signal attenuation caused by the shorter T-2 of metabolites. Precise adjustment of higher-order shims, which was achieved with FASTMAP, was crucial to benefit from this high magnetic field. Sensitivity improvements were evident from single-shot spectra and from the direct detection of glucose at 5.23 ppm in 8-ml volumes. The linewidth of the creatine methyl resonance was at best 9 Hz. In spite of the increased linewidth of singlet resonances at 7 T, the ability to resolve overlapping multiplets of J-coupled spin systems, such as glutamine and glutamate, was substantially increased. Characteristic spectral patterns of metabolites, e.g., myo-inositol and taurine, were discernible in the in vivo spectra, which facilitated an unambiguous signal assignment. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 44 条
[1]  
ANDRIANY G, 2000, P 8 ANN M ISMRM DENV, P563
[2]  
Barfuss H, 1990, NMR Biomed, V3, P31, DOI 10.1002/nbm.1940030106
[3]  
Bartha R, 2000, MAGNET RESON MED, V44, P185, DOI 10.1002/1522-2594(200008)44:2<185::AID-MRM4>3.0.CO
[4]  
2-V
[5]   AMINO-ACID NEUROTRANSMITTERS IN POSTMORTEM HUMAN-BRAIN ANALYZED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
ELLISON, DW ;
BEAL, MF ;
MARTIN, JB .
JOURNAL OF NEUROSCIENCE METHODS, 1987, 19 (04) :305-315
[6]   H-1 SPECTROSCOPIC IMAGING OF RAT-BRAIN AT 7 TESLA [J].
FERNANDEZ, EJ ;
MAUDSLEY, AA ;
HIGUCHI, T ;
WEINER, MW .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (01) :107-119
[7]   3-DIMENSIONAL H-1 SPECTROSCOPIC IMAGING OF CEREBRAL METABOLITES IN THE RAT USING SURFACE COILS [J].
FERNANDEZ, EJ ;
MAUDSLEY, AA ;
HIGUCHI, T ;
WEINER, MW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (06) :965-974
[8]   LOCALIZED PROTON NMR-SPECTROSCOPY IN DIFFERENT REGIONS OF THE HUMAN-BRAIN INVIVO - RELAXATION-TIMES AND CONCENTRATIONS OF CEREBRAL METABOLITES [J].
FRAHM, J ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD ;
HANICKE, W ;
SAUTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) :47-63
[9]  
Govindaraju V, 2000, NMR BIOMED, V13, P129, DOI 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO
[10]  
2-V