Increased burst pressure in gastrointestinal staple-lines using reinforcement with a bioprosthetic material

被引:49
作者
Downey, DM
Harre, JG
Dolan, JR
机构
[1] Kessler Med Ctr, Dept Surg, Keesler AFB, MS 39534 USA
[2] Kessler Med Ctr, Clin Res Lab, Keesler AFB, MS 39534 USA
关键词
intestinal anastomosis; staple-line; leak; burst pressure;
D O I
10.1381/096089205774859254
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Leakage at an anastomosis is a major and often catastrophic complication of gastrointestinal (GI) surgery. Staple-line reinforcement with one of the several materials commercially available has been utilized to reduce the incidence of this complication. The bioprosthetic material, small intestinal submucosa (SIS, Surgisis (R); Cook, Inc., Bloomington, IN) has found widespread applications in surgery. However, its ability to improve the durability of staple-lines in GI surgery in terms of burst pressure has not been documented. We hypothesized that SIS reinforcement of staple-lines in healthy living GI tissue would increase durability, as determined by leak rates at increased intraluminal pressures, compared to unreinforced staple-lines. Methods: Two healthy Yorkshire-Cross pigs were subjected to midline laparotomy and underwent small intestinal division (n=28) with GIA stapling devices. Half of the staple-lines were reinforced with SIS. The staple-lines were then exposed to increased intraluminal pressures by means of a constant-rate dye solution infusion, until staple-lines exhibited visible leakage of the dye solution. The intraluminal pressure was recorded at the time of visible leakage. Results: Staple-lines reinforced with SIS had significantly better durability as determined by analysis of variance and Kaplan-Meier survival calculations, with respect to leak rate as a function of intraluminal pressure (P < 0.003). The mean burst pressure of the unreinforced staple-lines was 53 mmHg, while those staple-lines reinforced with SIS had a mean burst pressure of 83 mmHg. Conclusion: Reinforcement of stapled GI anastomoses with SIS significantly increases anastomotic burst pressure. These findings suggest a role for this material in GI surgery.
引用
收藏
页码:1379 / 1383
页数:5
相关论文
共 25 条
[21]   Early bursting strength of human colon anastomoses - an in vitro study comparing current anastomotic techniques [J].
Schwab, R ;
Wessendorf, S ;
Gutcke, A ;
Becker, HP .
LANGENBECKS ARCHIVES OF SURGERY, 2002, 386 (07) :507-511
[22]   Surgical staple metalloptysis after apical bullectomy: A reaction to bovine pericardium? [J].
Shamji, MF ;
Maziak, DE ;
Shamji, FM ;
Matzinger, FRK ;
Perkins, DG .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :258-261
[23]   Reinforcing gastric staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparoscopic Roux-en-Y gastric bypass [J].
Shikora, SA ;
Kim, JJ ;
Tarnoff, ME .
OBESITY SURGERY, 2003, 13 (01) :37-44
[24]   Tissue response to biomaterials used for staple-line reinforcement in lung resection - A comparison between expanded polytetrafluoroethylene and bovine pericardium [J].
Vaughn, CC ;
Vaughn, PL ;
Vaughn, CC ;
Sawyer, P ;
Manning, M ;
Anderson, D ;
Roseman, L ;
Herbst, TJ .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (03) :259-265
[25]  
Wassner JD, 1977, SURGERY, V82, P393