Evaluation of Digital and Optical Refractometers for Assessing Failure of Transfer of Passive Immunity in Dairy Calves

被引:55
作者
Elsohaby, I. [1 ,2 ]
McClure, J. T. [1 ]
Keefe, G. P. [1 ]
机构
[1] Univ Prince Edward Isl, Dept Hlth Management, Atlantic Vet Coll, Charlottetown, PE C1A 4P3, Canada
[2] Zagazig Univ, Dept Anim Med, Fac Vet Med, Infect Dis, Zagazig 44511, Sharkia Provinc, Egypt
关键词
Immunoglobulin G; Radial immunodiffusion assay; Serum total protein; IMMUNOGLOBULIN-G CONCENTRATION; CAPRYLIC-ACID FRACTIONATION; COLOSTRAL IMMUNOGLOBULINS; CALF; MANAGEMENT; ABSORPTION; MORTALITY; PROTEIN; HEIFER; GROWTH;
D O I
10.1111/jvim.12560
中图分类号
S85 [动物医学(兽医学)];
学科分类号
090604 [动物药学];
摘要
BackgroundFailure of transfer of passive immunity (FTPI) is the underlying predisposing risk factor for most early losses in dairy calves. Refractometers, either optical or digital, can be used to assess FTPI as a part of calf health monitoring program on dairy operations. ObjectivesTo evaluate the performance of and differences between digital Brix and optical refractometers for assessing FTPI in dairy calves. AnimalsTwo hundred Holstein calves from 1 to 11days of age. MethodsA cross-sectional study was designed to measure serum IgG concentration by radial immunodiffusion (RID) assay, digital Brix and optical refractometers. The correlation coefficients (r) between the 2 refractometers were plotted against each other and against the measured IgG concentration from RID. The Se, Sp, and accuracy of digital Brix and optical refractometers for assessing FTPI using previously recommended cut-offs were calculated. A receiver operating characteristic curve was created and used to identify the optimal cut-off for this dataset. ResultsThe RID IgG concentration was positively correlated with digital Brix (r=0.79) and optical (r=0.74) refractometers. The best combination of Se (85.5%), Sp (82.8%), and accuracy (83.5%) of digital Brix refractometer was at 8.3%Brix. For optical refractometer, the best combination of Se (80%), Sp (80.7%), and accuracy (80.5%) was at 5.5g/dL. Conclusions and Clinical ImportanceBoth refractometers exhibited utility in assessing FTPI in dairy calves.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 30 条
[1]
[Anonymous], [No title captured]
[2]
An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle [J].
Bielmann, V. ;
Gillan, J. ;
Perkins, N. R. ;
Skidmore, A. L. ;
Godden, S. ;
Leslie, K. E. .
JOURNAL OF DAIRY SCIENCE, 2010, 93 (08) :3713-3721
[3]
Comparison of refractometers and test endpoints in the measurement of serum protein concentration to assess passive transfer status in calves [J].
Calloway, CD ;
Tyler, JW ;
Tessman, RK ;
Hostetler, D ;
Holle, J .
JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2002, 221 (11) :1605-1608
[4]
Dairy U.S, 2007, REFERENCE DAIRY CA 1, P1007
[5]
Evaluation of a Brix refractometer to estimate serum immunoglobulin G concentration in neonatal dairy calves [J].
Deelen, S. M. ;
Ollivett, T. L. ;
Haines, D. M. ;
Leslie, K. E. .
JOURNAL OF DAIRY SCIENCE, 2014, 97 (06) :3838-3844
[6]
Faber S. N., 2005, Professional Animal Scientist, V21, P420
[8]
THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[9]
Lachenbruch PA, 1998, STAT MED, V17, P2207, DOI 10.1002/(SICI)1097-0258(19981015)17:19<2207::AID-SIM920>3.0.CO
[10]
2-Y