Quantitative polymerase chain reaction: a framework for improving the quality of results and estimating uncertainty of measurement

被引:12
作者
Griffiths, Kate R. [1 ]
Burke, Daniel G. [1 ]
Emslie, Kerry R. [1 ]
机构
[1] Natl Measurement Inst, W Lindfield, NSW 2070, Australia
关键词
REAL-TIME PCR; DNA FRAGMENT RATIOS; METROLOGICAL TRACEABILITY; GM QUANTIFICATION; METHOD VALIDATION; BONE MEAL; PERFORMANCE; INHIBITORS; PRECISION; TRENDS;
D O I
10.1039/c1ay05069a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
International comparability of quantitative polymerase chain reaction (qPCR) measurement results is critical for applied fields within industry, healthcare and forensics and may be achieved through traceability to the International System of Units, the SI. This process requires determining the accuracy of the quantitative result by estimation of the measurement uncertainty (MU). Here we present a relatively simple process for estimating MU for quantitative DNA measurements produced by qPCR. A worked example is given in which the qPCR method has been divided into four parts: DNA extraction; preparation of calibration curves; qPCR set-up and data analysis. A framework is provided in comprehensive tables that allow the identification of most potential sources of variation and bias. We show that each source can be either eliminated from the measurement process or captured in the MU data. The necessary data for MU estimation are relatively easy to gather but the combined uncertainty is only representative if all sources of variation have been incorporated. Although qPCR is given as an example, the principles apply to other nucleic acid measurements.
引用
收藏
页码:2201 / 2211
页数:11
相关论文
共 60 条
[1]  
[Anonymous], 2008, EVALUATION MEASUREME, P8
[2]  
[Anonymous], 2003, ISO17511
[3]  
[Anonymous], 2005, ISO21571
[4]   Achieving metrological traceability in chemical and bioanalytical measurement [J].
Barwick, Vicki ;
Wood, Steve .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (06) :785-799
[5]  
Bentley R. E., 2005, MONOGRAPH NAT MEAS I, V1
[6]   Comparison of Methods for Accurate Quantification of DNA Mass Concentration with Traceability to the International System of Units [J].
Bhat, Somanath ;
Curach, Natalie ;
Mostyn, Thomas ;
Bains, Gursharan Singh ;
Griffiths, Kate R. ;
Emslie, Kerry R. .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7185-7192
[7]   Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number [J].
Bhat, Somanath ;
Herrmann, Jan ;
Armishaw, Paul ;
Corbisier, Philippe ;
Emslie, Kerry R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) :457-467
[8]   Potential Primary Measurement Tool for the Quantification of DNA [J].
Brennan, Ryan G. ;
Rabb, Savelas A. ;
Holden, Marcia J. ;
Winchester, Michael R. ;
Turk, Gregory C. .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3414-3420
[9]  
Bustin S. A., 2008, EUR PHARM REV, P19
[10]   Real-time, fluorescence-based quantitative PCR: a snapshot of current procedures and preferences [J].
Bustin, SA .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2005, 5 (04) :493-498