Potential Primary Measurement Tool for the Quantification of DNA

被引:17
作者
Brennan, Ryan G. [1 ,3 ]
Rabb, Savelas A. [1 ]
Holden, Marcia J. [2 ]
Winchester, Michael R. [1 ]
Turk, Gregory C. [1 ]
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Div Biochem Sci, Gaithersburg, MD 20899 USA
[3] George Washington Univ, Dept Chem, Washington, DC 20052 USA
关键词
PLASMA-MASS SPECTROMETRY; HIGH-EFFICIENCY NEBULIZER; ELEMENTAL ANALYSIS; QUANTITATIVE DETECTION; NUCLEIC-ACIDS; ICP-OES; PHOSPHORUS; ASSAY; PERFORMANCE; SAMPLE;
D O I
10.1021/ac802688x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated sample introduction system, utilizing a demountable direct injection high-efficiency nebulizer (d-DIHEN), is successfully incorporated for the first time with an inductively coupled plasma optical emission spectrometer (ICP-OES) for the measurement of the phosphorus content in acid-digested nucleotides and deoxyribonucleic acid (DNA). With this experimental setup, the solution uptake rate and volume are reduced from 170 to 30 mu L min(-1) and from 10, to 2.4 mL, respectively, thereby reducing the required DNA sample mass for solutions containing 3 mu g g(-1) P from 300 to 72 mu g of DNA, in comparison to previous analyses in our laboratory using a glass concentric nebulizer with cyclonic spray chamber arrangement The use of direct injection also improves P (1) 213.617 nm sensitivity by a factor of 4 on average. A high-performance (HP) methodology in combination with the previous sample introduction system and ICP-OES provides simultaneous, time-correlated internal standardization and drift correction resulting in relative expanded uncertainties (% U) for the P mass fractions in the range of 0.1-0.4 (95% confidence level) for most of the thymidine 5'-monophosphate (TMP), calf thymus DNA (CTDNA), and plasmid DNA (PLDNA) analyses. The d-DIHEN with HP-ICP-OES methodology allows for the quantification of DNA mass at P mass fractions as low as 0.5 mu g g(-1), further reducing the required DNA mass to 12 mu g, with small uncertainty (<= 0.4%). This successful approach will aid in the development and certification of nucleic acid certified reference materials (CRMs), particularly for these samples that are typically limited in volume.
引用
收藏
页码:3414 / 3420
页数:7
相关论文
共 36 条
[1]   A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry [J].
Acon, BW ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1885-1893
[2]   Quantitative detection system for maize sample containing combined-trait genetically modified maize [J].
Akiyama, H ;
Watanabe, T ;
Wakabayashi, K ;
Nakade, S ;
Yasui, S ;
Sakata, K ;
Chiba, R ;
Spiegelhalter, F ;
Hino, A ;
Maitani, T .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7421-7428
[3]   The potential for elemental analysis in biotechnology [J].
Baranov, VI ;
Quinn, ZA ;
Bandura, DR ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1148-1152
[4]   A sensitive and quantitative element-tagged immunoassay with ICPMS detection [J].
Baranov, VI ;
Quinn, Z ;
Bandura, DR ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1629-1636
[5]   Elemental tagging in inorganic mass spectrometric bioanalysis [J].
Bettmer, J. ;
Jakubowski, N. ;
Prange, A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (01) :7-11
[6]   Nano-HPLC-inductively coupled plasma mass spectrometry for arsenic speciation [J].
Brennan, Ryan G. ;
Murdock, Su-Ann E. O'Brien ;
Farmand, Maryam ;
Kahen, Kaveh ;
Samii, Salar ;
Gray, Jessica M. ;
Montaser, Akbar .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) :1199-1205
[7]   DNA quantification approach by GE-ICP-SFMS and complementary total phosphorus determination by ICP-SFMS [J].
Bruechert, Wolfram ;
Bettmer, Joerg .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1271-1276
[8]   Revised UV extinction coefficients for nucleoside-5'-monophosphates and unpaired DNA and RNA [J].
Cavaluzzi, MJ ;
Borer, PN .
NUCLEIC ACIDS RESEARCH, 2004, 32 (01) :e13
[9]  
CHARGAFF E, 1948, J BIOL CHEM, V173, P327
[10]   Mixed-gas inductively coupled plasma atomic emission spectrometry using a direct injection high efficiency nebulizer [J].
Chirinos, JR ;
Kahen, K ;
O'Brien, SE ;
Montaser, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :128-135