Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI

被引:156
作者
Sled, JG
Pike, GB
机构
[1] Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Montreal, PQ H3A 2B4, Canada
关键词
intensity nonuniformity; magnetic resonance imaging; RF held inhomogeneity; shading artifact;
D O I
10.1109/42.730409
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging an elliptically shaped object using 1.5-T magnets and circularly polarized RF coils. This first principle analysis clarifies, for the general case of conducting objects, the relationship between the excitation field and the reception sensitivity of circularly and linearly polarized coils. The results, validated experimentally using a standard spin-echo imaging sequence and an in vivo B-1 field mapping technique, are shown to be accurate to within 1%-2% root mean square, suggesting that these electromagnetic interactions with the object account for most of the intensity nonuniformity observed.
引用
收藏
页码:653 / 662
页数:10
相关论文
共 27 条
[1]  
Abramowitz M., 1970, HDB MATH FUNCTIONS
[2]   A complete method for the computations of Mathieu characteristic numbers of integer orders [J].
Alhargan, FA .
SIAM REVIEW, 1996, 38 (02) :239-255
[3]  
[Anonymous], 1979, STUDIA SEMIOTYCZNE, V9, P63
[4]   NUCLEAR INDUCTION [J].
BLOCH, F ;
HANSEN, WW ;
PACKARD, M .
PHYSICAL REVIEW, 1946, 69 (3-4) :127-127
[5]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[6]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[7]  
*CRC, 1974, CRC HDB CHEM PHYS, pE126
[8]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781
[9]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[10]   On the SAR and field inhomogeneity of birdcage coils loaded with the human head [J].
Jin, JM ;
Chen, J .