Flow injection amperometry for the determination of iodate in iodized table salt

被引:58
作者
Jakmunee, J [1 ]
Grudpan, K [1 ]
机构
[1] Chiang Mai Univ, Inst Sci & Technol Res & Dev, Dept Chem, Fac Sci, Chiang Mai 50200, Thailand
关键词
iodate; flow injection analysis; amperometry; voltammetry; iodized salt;
D O I
10.1016/S0003-2670(01)00798-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple flow injection amperometric system for determination of iodate has been developed. Cyclic voltammetry was used to study reactions of iodate, iodide and iodine on a glassy carbon electrode. A single line manifold of the dow system consists of a pulse-free reagent propulsion using a simple Mariotte bottle, a home-made injection valve, and a cross flow electrochemical cell with a potentiostat for control a potential of glassy carbon working electrode at +200 mV versus Ag/AgCl electrode. Using a solution of 1.0% w/v NaCl, 0.02% w/v KI and 0.1 M HCl as a reagent and a flow rate of 2 ml/min, a linear calibration up to 25 mg/l IO3- with a detection limit of 0.5 mg/l IO3- was obtained. Relative standard deviation for 10 injections of 10 mg/l IO3- solution was 1.7%. A sample throughput of 35 injections per hour was achieved. The system was successfully applied for determination of iodate in iodized table salts, validating by the AOAC titrimetric method. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 19 条
[1]   Determination of iodide and iodate by ion chromatography with postcolumn reaction and UV/visible detection [J].
Bichsel, Y ;
von Gunten, U .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :34-38
[2]   Combination of suppressed and non-suppressed ion chromatography with atmospheric pressure ionization mass spectrometry for the determination of anions [J].
Buchberger, W ;
Ahrer, W .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :99-106
[3]  
Cunniff P, 1990, OFFICIAL METHODS ANA, P31
[4]   Extraction equilibrium of the ion-associate of periodate with amiloride hydrochloride and simultaneous spectrophotometric determination of periodate and iodate by liquid-liquid extraction [J].
El-Shahawi, MS .
ANALYTICA CHIMICA ACTA, 1997, 356 (01) :85-91
[5]   Spectrophotometric determination of periodate or iodate ions by liquid-liquid extraction as an ion-pair using tetramethylammonium iodide [J].
ElShahawi, MS ;
AlHashemi, FA .
TALANTA, 1996, 43 (12) :2037-2043
[6]   Flow-injection simultaneous determination of iodate and periodate by spectrophotometric and spectrofluorometric detection [J].
Ensafi, AA ;
Dehaghi, GB .
ANALYTICAL SCIENCES, 2000, 16 (01) :61-64
[7]  
Gilman A. G., 1985, PHARMACOL BASIS THER, P964
[8]   FLOW-INJECTION ANALYSIS USING AN AQUARIUM AIR PUMP [J].
GRUDPAN, K ;
TAYLOR, C ;
SITTER, H ;
KELLER, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (10-11) :882-884
[9]  
Kosminsky L, 1999, ELECTROANAL, V11, P623, DOI 10.1002/(SICI)1521-4109(199907)11:9<623::AID-ELAN623>3.3.CO
[10]  
2-1