Comparison of source localization of interictal epileptic spike potentials in patients estimated by the dipole tracing method with the focus directly recorded by the depth electrodes

被引:28
作者
Homma, I
Masaoka, Y
Hirasawa, K
Yamane, F
Hori, T
Okamoto, Y
机构
[1] Showa Univ, Sch Med, Dept Physiol 2, Shinagawa Ku, Tokyo 1428555, Japan
[2] Tokyo Womens Med Univ, Dept Neurosurg, Shinjuku Ku, Tokyo, Japan
[3] Chiba Inst Technol, Dept Elect Engn, Narashino, Chiba 2750016, Japan
关键词
dipole tracing method; scalp-skull-brain head model; epileptic spike; temporal seizures; electoencephalograms; intracerebral depth electrodes; amygdala;
D O I
10.1016/S0304-3940(01)01746-3
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of the study was to investigate the accuracy of location of equivalent current dipoles estimated by the dipole tracing method (DT) utilizing a realistic 3-shell (scalp-skull-brain) head model (SSB-DT). Three patients with intractable complex partial seizures, diagnosed as having typical temporal seizures were investigated. We recorded the interictal spike potentials with surface electrodes (International 10/20 system) and with intracerebral depth electrodes simultaneously. We compared the location of dipoles of the spikes estimated by the SSB-DT with the focus of the spikes determined by the recording from the depth electrodes. We found that the location of the dipoles estimated by SSB-DT corresponded to the location of the depth electrodes, which could record the epileptic spikes. This finding proved that SSB-DT is reliable and valid for estimating neural activity in deep locations such as the limbic system. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 12 条
[1]   INTERICTAL AND ICTAL ACTIVITY RECORDED WITH SUBDURAL ELECTRODES DURING PREOPERATIVE EVALUATION FOR SURGICAL-TREATMENT OF EPILEPSY [J].
BLOM, S ;
FLINK, R ;
HETTA, J ;
HILTONBROWN, P ;
HOFFSTEDT, C ;
OSTERMAN, PO ;
SPANNARE, B .
JOURNAL OF EPILEPSY, 1989, 2 (01) :9-20
[2]   MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
COHEN, D ;
CUFFIN, BN ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, JG ;
SCHOMER, DL .
ANNALS OF NEUROLOGY, 1990, 28 (06) :811-817
[3]   TESTS OF EEG LOCALIZATION ACCURACY USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
CUFFIN, BN ;
COHEN, D ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, J ;
SCHOMER, D .
ANNALS OF NEUROLOGY, 1991, 29 (02) :132-138
[5]  
FLINK R, 2000, CLIN NEUROPHYSIOL, V53, P1
[6]   ELECTRIC-DIPOLE TRACING IN THE BRAIN BY MEANS OF THE BOUNDARY ELEMENT METHOD AND ITS ACCURACY [J].
HE, B ;
MUSHA, T ;
OKAMOTO, Y ;
HOMMA, S ;
NAKAJIMA, Y ;
SATO, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (06) :406-414
[7]   LOCATION OF ELECTRIC-CURRENT SOURCES IN THE HUMAN BRAIN ESTIMATED BY THE DIPOLE TRACING METHOD OF THE SCALP-SKULL-BRAIN (SSB) HEAD MODEL [J].
HOMMA, S ;
MUSHA, T ;
NAKAJIMA, Y ;
OKAMOTO, Y ;
BLOM, S ;
FLINK, R ;
HAGBARTH, KE ;
MOSTROM, U .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 91 (05) :374-382
[8]   Movement related cortical source for elbow flexion in patients with brachial plexus injury after intercostal-musculocutaneous nerve crossing [J].
Kanamaru, A ;
Homma, I ;
Hara, T .
NEUROSCIENCE LETTERS, 1999, 274 (03) :203-206
[9]   STEREOTAXIC INVESTIGATION OF LIMBIC EPILEPSY USING A MULTIMODAL IMAGE-ANALYSIS SYSTEM - TECHNICAL NOTE [J].
LEVESQUE, MF ;
ZHANG, JX ;
WILSON, CL ;
BEHNKE, EJ ;
HARPER, RM ;
LUFKIN, RB ;
ENGEL, J ;
CRANDALL, PH .
JOURNAL OF NEUROSURGERY, 1990, 73 (05) :792-797
[10]   The source generator of respiratory-related anxiety potential in the human brain [J].
Masaoka, Y ;
Homma, I .
NEUROSCIENCE LETTERS, 2000, 283 (01) :21-24