Immunosensor for the determination of Staphylococcus aureus using a tyrosinase-mercaptopropionic acid modified electrode as an amperometric transducer

被引:46
作者
Escamilla-Gomez, Vanessa [1 ]
Campuzano, Susana [1 ]
Pedrero, Maria [1 ]
Pingarron, Jose M. [1 ]
机构
[1] Univ Complutense Madrid, Fac CC Quim, Dept Quim Analit, E-28040 Madrid, Spain
关键词
electrochemical immunosensor; Staphylococcus aureus; self-assembled monolayer modified electrodes;
D O I
10.1007/s00216-007-1810-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An amperometric immunosensor for the quantification of Staphylococcus aureus based on the coimmobilization of rabbit immunoglobulin G (RbIgG) and tyrosinase on a mercaptopropionic acid self-assembled monolayer modified gold electrode is reported. A competitive mode in which protein-A-bearing S. aureus cells and antiRbIgG labeled with alkaline phosphatase (AP) compete for the binding sites of immobilized RbIgG was used. Monitoring of the affinity reaction was carried out by the amperometric detection at -0.15 V of phenol generated in the enzyme reaction with AP, at the tyrosinase-modified electrode through the electrochemical reduction of the o-quinone formed. Optimization of the working variables, such as the immunosensor composition and incubation times, the applied potential, the working pH and the concentration of phenyl phosphate used as the AP substrate, was carried out. Under the optimized conditions, both the repeatability of the measurements and the reproducibility of the responses obtained with different immunosensors yielded relative standard deviation values for the steady-state current lower than 10%. The immunosensor showed a dynamic range from 4.4 x 10(5) to 1.8 x 10(7) S. aureus cells mL(-1), with a detection limit of 1.7 x 10(5) cells mL(-1). The limit of detection was remarkably improved by subjecting S. aureus cells to wall lysis by heat treatment. The value obtained was 2.3 x 10(3) cells mL(-1), which is adequate for the monitoring of S. aureus contamination levels in some foodstuffs. As an application, milk samples spiked with bacteria at the 4.8 x 10(3) cells mL(-1) level were analyzed.
引用
收藏
页码:837 / 845
页数:9
相关论文
共 33 条
[1]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[2]   A peroxidase-tetrathiafulvalene biosensor based on self-assembled monolayer modified Au electrodes for the flow-injection determination of hydrogen peroxide [J].
Campuzano, S ;
Pedrero, M ;
Pingarrón, JA .
TALANTA, 2005, 66 (05) :1310-1319
[3]   An integrated bienzyme glucose oxidase-fructose dehydrogenase-tetrathiafulvalene-3-mercaptopropionic acid-gold electrode for the simultaneous determination of glucose and fructose [J].
Campuzano, S ;
Loaiza, SA ;
Pedrero, M ;
de Villena, FJM ;
Pingarrón, JM .
BIOELECTROCHEMISTRY, 2004, 63 (1-2) :199-206
[4]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[5]   Immunomagnetic separation and MS/SPR end-detection combined procedure for rapid detection of Staphylococcus aureus and protein A [J].
Chen, Lingli ;
Deng, Le ;
Liu, Linlin ;
Peng, Zhihui .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1487-1492
[6]  
Dan D., 2007, TALANTA, V71, P1257
[7]   Immunosensor for Mycobacterium tuberculosis on screen-printed carbon electrodes [J].
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2035-2043
[8]   Development of an amperometric immunosensor for the quantification of staphylococcus aureus using self-assembled monolayer-modiried electrodes as immobilization platforms [J].
Escamilla-Gomez, Vanessa ;
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose M. .
ELECTROANALYSIS, 2007, 19 (14) :1476-1482
[9]   Adsorption of immunoglobulin G on carbon paste electrodes as a basis for the development of immunoelectrochemical devices [J].
FernandezSanchez, C ;
CostaGarcia, A .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (05) :403-413
[10]   Entrapment of biomolecules in sol-gel matrix for applications in biosensors: Problems and future prospects [J].
Gupta, R. ;
Chaudhury, N. K. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2387-2399