Framework for multivariate selectivity analysis, part I: Theoretical and practical merits

被引:18
作者
Brown, CD [1 ]
Ridder, TD [1 ]
机构
[1] InLight Solut, Albuquerque, NM 87106 USA
关键词
multivariate; selectivity; sensitivity; net analyte signal; figures of merit;
D O I
10.1366/0003702054280621
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A number of definitions of multivariate selectivity have been proposed in the literature. Arguably, the one that enjoys the greatest chemometric attention has been the net analyte signal (NAS) based definitions of Lorber and Zinn. Recent works have suggested that similar inference can be made for inverse least-squares calibration methods (e.g., principal components regression). However, the properties of inverse calibration methods are markedly different than classical methods, so in many practical cases involving inverse models classically derived figures of merit cannot be transparently interpreted. In Part I of this work, we discuss a selectivity framework that is theoretically consistent regardless of the calibration method. Importantly, it is also experimentally measurable, either through controlled selectivity experiments, or through analysis on opportunistically acquired sample measurements. It is statistically advantageous to use the former if such control is achievable. Selectivity is defined to be a function of the change in predicted analyte concentration that will result from a change in the concentration of an interferant, an approach consistent with traditional definitions of analytical selectivity and National Committee for Clinical Laboratory Standards recommendations for interference testing. Unlike the NAS-based definition of selectivity, the definition discussed herein is relevant to only a particular analyte-interferant pair. The theoretical and experimental aspects of this approach are illustrated with simulated data herein and in Part II of this paper, which investigates several experimental near-infrared data sets.
引用
收藏
页码:787 / 803
页数:17
相关论文
共 28 条
[1]  
[Anonymous], 1987, BINDING CONSTANTS ME
[2]   Pure component selectivity analysis of multivariate calibration models from near-infrared spectra [J].
Arnold, MA ;
Small, GW ;
Xiang, D ;
Qui, J ;
Murhammer, DW .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2583-2590
[3]   IMPROVEMENT IN THE DEFINITIONS OF SENSITIVITY AND SELECTIVITY [J].
BERGMANN, G ;
VONOEPEN, B ;
ZINN, P .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2522-2526
[4]   Theory of net analyte signal vectors in inverse regression [J].
Bro, R ;
Andersen, CM .
JOURNAL OF CHEMOMETRICS, 2003, 17 (12) :646-652
[5]   Discordance between net analyte signal theory and practical multivariate calibration [J].
Brown, CD .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :4364-4373
[6]   Derivative preprocessing and optimal corrections for baseline drift in multivariate calibration [J].
Brown, CD ;
Vega-Montoto, L ;
Wentzell, PD .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1055-1068
[7]  
BROWN PJ, 1993, MEASUREMENT REGRESSI, P22
[8]   Selectivity and specificity in analytical chemistry. General considerations and attempt of a definition and quantification [J].
Danzer, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (05) :397-402
[9]   Efficient computation of net analyte signal vector in inverse multivariate calibration models [J].
Faber, NM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5108-5110
[10]   Quantifying selectivity in spectrophotometric multicomponent analysis [J].
Faber, NM ;
Ferré, J ;
Boqué, R ;
Kalivas, JH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (06) :352-361