Extension of separation range in capillary isoelectric focusing for resolving highly basic biomolecules

被引:27
作者
Mohan, D [1 ]
Lee, CS [1 ]
机构
[1] Univ Maryland, Coll Life Sci, Dept Chem & Biochem, College Pk, MD 20742 USA
关键词
isoelectric focusing; isoelectric point; tetramethylenediamine; ampholytes; pharmalytes; bradykinin; cytochromes; proteins; peptides;
D O I
10.1016/S0021-9673(02)01442-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The non-availability of commercial carrier ampholytes in the pH range greater than I I has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 14 条
[1]   New zwitterionic detergents improve the analysis of membrane proteins by two-dimensional electrophoresis [J].
Chevallet, M ;
Santoni, V ;
Poinas, A ;
Rouquié, D ;
Fuchs, A ;
Kieffer, S ;
Rossignol, M ;
Lunardi, J ;
Garin, J ;
Rabilloud, T .
ELECTROPHORESIS, 1998, 19 (11) :1901-1909
[2]   Capillary isoelectric focusing: The problem of protein solubility [J].
Conti, M ;
Galassi, M ;
Bossi, A ;
Righetti, PG .
JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) :237-245
[3]   SCREENING OF UMBILICAL-CORD BLOOD HEMOGLOBINS BY ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
CONTI, M ;
GELFI, C ;
RIGHETTI, PG .
ELECTROPHORESIS, 1995, 16 (08) :1485-1491
[4]  
Görg A, 1999, ELECTROPHORESIS, V20, P712
[5]  
Manabe T, 1999, ELECTROPHORESIS, V20, P3677, DOI 10.1002/(SICI)1522-2683(19991201)20:18<3677::AID-ELPS3677>3.3.CO
[6]  
2-L
[7]   Extraction of membrane proteins by differential solubilization for separation using two-dimensional gel electrophoresis [J].
Molloy, MP ;
Herbert, BR ;
Walsh, BJ ;
Tyler, MI ;
Traini, M ;
Sanchez, JC ;
Hochstrasser, DF ;
Williams, KL ;
Gooley, AA .
ELECTROPHORESIS, 1998, 19 (05) :837-844
[8]   SAMPLE APPLICATION BY IN-GEL REHYDRATION IMPROVES THE RESOLUTION OF 2-DIMENSIONAL ELECTROPHORESIS WITH IMMOBILIZED PH GRADIENTS IN THE FIRST-DIMENSION [J].
RABILLOUD, T ;
VALETTE, C ;
LAWRENCE, JJ .
ELECTROPHORESIS, 1994, 15 (12) :1552-1558
[9]   Improvement of the solubilization of proteins in two-dimensional electrophoresis with immobilized pH gradients [J].
Rabilloud, T ;
Adessi, C ;
Giraudel, A ;
Lunardi, J .
ELECTROPHORESIS, 1997, 18 (3-4) :307-316
[10]  
RODRIGUEZDIAZ R, 1907, HDB CAPILLARY ELECTR, P101