Biomolecular immobilization on conducting polymers for biosensing applications

被引:368
作者
Ahuja, Tarushee
Mir, Irfan Ahmad
Kumar, Devendra
Rajesh
机构
[1] CSIR, Intellectual Property Management Div, New Delhi 110067, India
[2] Univ Delhi, Delhi Coll Engn, Dept Appl Chem, Delhi 110042, India
关键词
conducting polymers; biosensors; electrochemical polymerization; physical adsorption; covalent immobilization; electrochemical immobilization; POLYPYRROLE BIENZYME ELECTRODES; HYDROGEN-PEROXIDE BIOSENSOR; GLUCOSE-OXIDASE; ENZYME ELECTRODE; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; CHOLESTEROL OXIDASE; ELECTROCHEMICAL IMMOBILIZATION; COVALENT ELECTROPOLYMERIZATION; POLYPHENOL OXIDASE;
D O I
10.1016/j.biomaterials.2006.09.046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A detail study on different aspects of biomolecule immobilization techniques on conducting polymers (CP) for applications in biosensors is described. Comparative studies are conducted in between the different mode of biomolecule immobilization techniques, viz. physical, covalent and electrochemical immobilization onto the conducting polymer films for the fabrication of electrochemical biosensors for clinical, food and environmental monitoring applications. This review focuses on the current status of biomolecule immobilization techniques on CP and their applications in the development of amperometric biosensors. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:791 / 805
页数:15
相关论文
共 223 条
  • [61] AN ELECTROCHEMICALLY GROWN POLYMER AS AN IMMOBILIZATION MATRIX FOR WHOLE CELLS - APPLICATION IN AN AMPEROMETRIC DOPAMINE SENSOR
    DESHPANDE, MV
    HALL, EAH
    [J]. BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) : 431 - 448
  • [62] DIAZ AF, 1988, ADV POLYM SCI, V84, P113
  • [63] ELECTROCHEMICAL POLYMERIZATION OF PYRROLE
    DIAZ, AF
    KANAZAWA, KK
    GARDINI, GP
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1979, (14) : 635 - 636
  • [64] THE APPLICATION OF FERROCENE-MODIFIED N-TYPE SILICON IN GLUCOSE BIOSENSORS
    DICKS, JM
    CARDOSI, MF
    TURNER, APF
    KARUBE, I
    [J]. ELECTROANALYSIS, 1993, 5 (01) : 1 - 9
  • [65] Detection of uric acid with a new type of conducting polymer-based enzymatic sensor by bipotentiostatic technique
    Dobay, R
    Harsányi, G
    Visy, C
    [J]. ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 187 - 194
  • [66] A simple conducting polymer-based biosensor for the detection of atrazine
    El Kaoutit, M
    Bouchta, D
    Zejli, H
    Izaoumen, N
    Temsamani, KR
    [J]. ANALYTICAL LETTERS, 2004, 37 (08) : 1671 - 1681
  • [67] Poly 3,4-ethylenedioxythiophene as an entrapment support for amperometric enzyme sensor
    Fabiano, S
    Tran-Minh, C
    Piro, B
    Dang, LA
    Pham, MC
    Vittori, O
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2002, 21 (1-2): : 61 - 67
  • [68] Nitric oxide biosensors based on Hb/phosphatidylcholine films
    Fan, CH
    Pang, JT
    Shen, PP
    Li, GX
    Zhu, DX
    [J]. ANALYTICAL SCIENCES, 2002, 18 (02) : 129 - 132
  • [69] ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS
    FOULDS, NC
    LOWE, CR
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1259 - 1264
  • [70] IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS
    FOULDS, NC
    LOWE, CR
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (22) : 2473 - 2478