Tissue glue in sutureless vitreoretinal surgery for the treatment of wound leakage

被引:23
作者
Batman, Cosar
Ozdamar, Yasemin
Aslan, Zlem
Sonmez, Kenan
Mutevelli, Seda
Zilelioglu, Guler
机构
[1] Ankara Ulucanlar Eye Res Hosp, Dept Vitreoretinal Surg, Ankara, Turkey
[2] Ankara Univ, Fac Med, Dept Ophthalmol, Ankara, Turkey
关键词
D O I
10.3928/15428877-20080301-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To assess the surgical outcomes of the use of tissue glue to close sclerotomy sites when required and the views of ultrasound biomicroscopy of the sclerotomy sites in 23- and 25-gauge vitrectomy systems. PATIENTS AND METHODS: A 25-gauge transconjunctival sutureless vitrectomy was performed in 38 eyes and a 23-gauge transconjunctival sutureless vitrectomy was performed in 46 eyes for various vitreoretinal diseases. Wound leakage occurred at the sclerotomy sites at the end of the surgery in 6 eyes with 23-gauge transconjunctival sutureless vitrectomy and 7 eyes with 25-gauge transconjunctival sutureless vitrectomy. The sclerotomy sites were closed by using tissue glue to prevent wound leakage and evaluated with ultrasound biomicroscopy postoperatively. RESULTS: No wound leakage was observed at the end of the surgical procedure or during the follow-up period. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of ultrasound biomicroscopy. CONCLUSION: The results demonstrated the efficacy of tissue glue for closing site ports when wound leakage is observed in transconjunctival sutureless vitreoretinal surgery.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 41 条
  • [1] Incidence of complications in 25-gauge transconjunctival sutureless vitrectomy based on the surgical indications
    Amato, Josh E.
    Akduman, Levent
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (02) : 100 - 102
  • [2] The use of fibrin adhesive in trabeculectomy: a pilot study
    Bahar, I.
    Lusky, M.
    Gaton, D.
    Robinson, A.
    Avisar, R.
    Weinberger, D.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (11) : 1430 - 1430
  • [3] Fibrin glue as a suture substitute: Histological evaluation of trabeculectomy in rabbit eyes
    Bahar, I
    Weinberger, D
    Lusky, M
    Avisar, R
    Robinson, A
    Gaton, D
    [J]. CURRENT EYE RESEARCH, 2006, 31 (01) : 31 - 36
  • [4] Pars plana vitrectomy: Comparison of three techniques for the treatment of diabetic vitreous hemorrhage
    Bahar, Irit
    Axer-Siegel, Ruth
    Weinberger, Dov
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (05) : 364 - 369
  • [5] Ocular surface sealants and adhesives
    Bhatia, Subir Singh
    [J]. OCULAR SURFACE, 2006, 4 (03) : 146 - 154
  • [6] Ultrasound biomicroscopy of sclerotomy sites after pars plana vitrectomy for diabetic vitreous hemorrhage
    Bhende, M
    Agraharam, SG
    Gopal, L
    Sumasri, K
    Sukumar, B
    George, J
    Sharma, T
    Shanmugam, MP
    Bhende, PS
    Shetty, NS
    Agrawal, RN
    Deshpande, DA
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1729 - 1736
  • [7] BOKER T, 1994, AM J OPHTHALMOL, V118, P813
  • [8] Problems associated with the 25-gauge transconjunctival sutureless vitrectomy system during and after surgery
    Byeon, Suk Ho
    Chu, Young Kwang
    Lee, Sung Chul
    Koh, Hyoung Jun
    Kim, Sung Soo
    Kwon, Oh Woong
    [J]. OPHTHALMOLOGICA, 2006, 220 (04) : 259 - 265
  • [9] Chan Stanley M, 2004, Curr Opin Ophthalmol, V15, P305, DOI 10.1097/00055735-200408000-00005
  • [10] Sutureless pars plana vitrectomy through self-sealing sclerotomies
    Chen, JC
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) : 1273 - 1275