Cerebral blood flow determinations using fluorescent microspheres: variations on the sedimentation method validated

被引:23
作者
Powers, KM
Schimmel, C
Glenny, RW
Bernards, CM
机构
[1] Univ Washington, Sch Med, Dept Anesthesiol, Seattle, WA 98195 USA
[2] Univ Washington, Sch Med, Dept Med, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
cerebral blood flow; regional blood flow; radioisotopes; microspheres; pigs; tissue digestion;
D O I
10.1016/S0165-0270(98)00180-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We validate a modification of the sedimentation method for measuring fluorescent microspheres (FM) that improves the determination of regional cerebral blood flow (rCBF). Our FM method for rCBF determination is compared to the radioactive microspheres (RM) method for rCBF measurement by simultaneous injection of one radioactive and two fluorescent labeled doses, at two separate time points, into the left ventricle of a pig. The pig was killed, the brain and spinal cord removed, and divided into 92 pieces averaging 0.83 g. Our modifications to FM analysis by sedimentation includes. 2 instead of 1 week of autolysis, pellet washing with 1% Triton X-100 instead of 0.25% Tween 80, phosphate buffer addition during rinse, fluorescent dye extraction using 2-ethoxyethylacetate instead of 2-(2-ethoxyethoxy)ethyl acetate and polypropylene instead of glass tubes. Comparing rCBF using Sc46 RM, to yellow-green and orange FM, yielded mean differences of 0.026 and 0.021 ml/min per piece, respectively. Sn-113 RM compared to blue-green and scarlet FM gave mean differences of - 0.010 and 0.137 ml/min per piece, respectively. All RM-FM differences, except those for scarlet FM, are within acceptable limits. This assay provides a reliable method for determining rCBF. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 14 条
[1]   QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES [J].
AUSTIN, RE ;
HAUCK, WW ;
ALDEA, GS ;
FLYNN, AE ;
COGGINS, DL ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :H280-H288
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[4]   Early time-dependent decompression for spinal cord injury: Vascular mechanisms of recovery [J].
Carlson, GD ;
Minato, Y ;
Okada, A ;
Gorden, CD ;
Warden, KE ;
Barbeau, JM ;
Biro, CL ;
Bahnuik, E ;
Bohlman, HH ;
Lamanna, JC .
JOURNAL OF NEUROTRAUMA, 1997, 14 (12) :951-962
[5]   FLUORESCENT VS RADIOACTIVE MICROSPHERE MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW [J].
CHIEN, GL ;
ANSELONE, CG ;
DAVIS, RF ;
VANWINKLE, DM .
CARDIOVASCULAR RESEARCH, 1995, 30 (03) :405-412
[6]   VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION [J].
GLENNY, RW ;
BERNARD, S ;
BRINKLEY, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (05) :2585-2597
[7]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79
[8]   MEASUREMENT OF BLOOD-FLOW TO THE ADRENAL CAPSULE, CORTEX AND MEDULLA IN DOGS AFTER HEMORRHAGE BY FLUORESCENT MICROSPHERES [J].
JASPER, MS ;
MCDERMOTT, P ;
GANN, DS ;
ENGELAND, WC .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1990, 30 (02) :159-167
[9]   THE MICROSPHERE METHOD FACILITATES STATISTICAL ASSESSMENT OF REGIONAL BLOOD-FLOW [J].
NOSE, Y ;
NAKAMURA, T ;
NAKAMURA, M .
BASIC RESEARCH IN CARDIOLOGY, 1985, 80 (04) :417-429
[10]   REGIONAL CEREBRAL TISSUE BLOOD-FLOW MEASURED BY THE COLORED MICROSPHERE METHOD DURING RETROGRADE CEREBRAL PERFUSION [J].
OOHARA, K ;
USUI, A ;
MURASE, M ;
TANAKA, M ;
ABE, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (04) :772-779